摘要 涂片显微镜检查是结核病实验室检查的重要手段之一,主要包括萋一尼(Ziehl—Neelsen,Z-N)染色技术和荧光染色技术。Z-N染色技术具有操作简便、廉价和特异度高等优点,目前使用广泛;荧光染色法较Z-N染色法检出率高而阅片,
出处 《中国防痨杂志》 CAS 2012年第2期127-128,共2页 Chinese Journal of Antituberculosis
  • 相关文献

参考文献7

  • 1Marais BJ, Brittle W, Painczyk K,et al. Use of light-emitting diode fluorescence microscopy to detect acid-fast bacilli in spu- tum. Clin Infect Dis, 2008,47(2) :203-207.
  • 2Van Deun A, Chonde TM, Gumusboga M, et al. Performance and acceptability of the FluoLED Easy module for tuberculosis fluorescence microscopy. Int J Tuberc Lung Dis,2008,12 (9) .- 1009-1014.
  • 3Kuhn W, Armstrong D, Atteberry S, et al. Usefulness of the paralens fluorescent microscope adaptor for the identification of mycobaeteria in both field and laboratory settings. Open Mi- crobiol J, 2010,4:30-33.
  • 4赵雁林,姜广路.中国结核病防治规划一痰涂片镜检标准化操作质量保证手册.北京:中国协和医科大学出版社,2009:5-13.
  • 5中国防痨协会基础专业委员会.结核病诊断细菌学检验规程.北京:中国教育文化出版社,2006:13-29.
  • 6Affolabi D, Torrea G, Odoun M, et al. Comparison of two LED fluorescence microscopy build-on modules for acid-fast smear microscopy. Int J Tuberc Lung Dis, 2010, 14 (2): 160-164.
  • 7尚美,刘冠,赵立平,夏辉,姜广路,黄海荣,赵雁林.发光二极管荧光显微镜实验室诊断效果评价[J].中国防痨杂志,2010,32(5):275-279. 被引量:27

二级参考文献1

共引文献35

同被引文献26

  • 1中华人民共和国卫生部疾病预防控制局,中国疾病预防控制中心.痰涂片镜检标准化操作及质量保证手册.北京:中国协和医科大学出版社,2009:4-9.
  • 2Urbanczik R. Present position of microscopy and of culture in diagnostic mycobacteriology. Zentralbl Bakteriol Mikrobiol Hyg, 1985,260(1) :81-87.
  • 3Steingart KR, Henry M, Ng V, et al. Fluorescence versus conventional sputum smear microscopy for tuberculosis: a sys ternatic review. I.ancet Infect Dis,2006, 6(9).. 570-581.
  • 4中国防痨协会基础专业委员会,结核病诊断实验室诊疗规程.北京:中国教育文化出版社,2006:30-46.
  • 5World Health Organization. Policy statement on fluorescent light-emitting diode (LED) microscopy for diagnosis of tuber- culosis. Geneva, 2010. (2011.8)[2011]. http.-//www, who. int/tb/laboratory/policy statements/en/index, html.
  • 6Minion J, Pai M, Ramsay A, et al. Comparison of LED and conventional fluorescence microscopy for detection of acid fast bacilli in a low-incidence setting. PLoS One, 2011, 6 (7) : e22495.
  • 7Anthony RM, Kolk AH, Kuijper S, et al. Light emitting di- odes for auramine O fluroreseene microscopic screening of My- cobacterium tuberculosis. Int J Tuberc Lung Dis, 2006,10 (9) : 1060-1062.
  • 8Van Deun A, Chonde TM, Gurnusboga M, et al. Performance and acceptability of the FluoLED Easy module for tuberculosis fluorescence microscopy. Int J Tuberc Lung Dis, 2008, 12 (9) : 1009-1014.
  • 9Minion J, Shenai S, Vadwai V, et al. Fading of auramine- stained mycobaeterial smears and implications for external quality assurance. J Clin Microbiol,2011,49(5):2024-2026.
  • 10王霖.检测痰样本中MPB64蛋白在结核病实验室诊断中的价值[J].中外健康文摘,2013,(5):88-89.