摘要 为提高ARL 4460直读光谱仪测定钢铁中8种常规元素分析结果的准确性,对一些主要的影响因素特别对碳及硫量测定的影响因素做了试验,并对其结果作了探讨,从中得到了一些有利于提高测定准确性和精密度的方法和措施,主要有以下几点:①改变了仪器出厂时设定的光源参数(冲洗时间由10s降为2s,预燃时间由7s降为6s,曝光时间由8s降为3s);②测定碳、硫、磷须用99.999%的高纯氩,且应控制其压力在0.30 MPa左右;③试样表面要干净平整,纹路清晰,应用细砂砂轮机处理试样表面;④制备定碳样品时,样品温度不能高于40℃,且保持其起始状态的纹路粗细程度;⑤分析室环境温度应保持恒定(25℃左右),每8h进行一次工作曲线的校正;⑥测定硫的试样若温度过高,宜先将其冷却至接近室温再作分析,且在分析时应至少取3个分布均匀的激发点,且需根据试样特点作现场校正曲线,用控制试样进行类型标准化。 Aiming to raising of accuracy of analytical results of 8 common elements in iron and steel by the ARL 4460 direct-reading spectrometer,testing for some influential factors,especially for determinations of carbon and sulfur,was made.The following measures were found to be effective for improving both the accuracy and precision of the determinations: ① light source parameters set during manufacturing were modified by lowering the time of development from 10 s to 2 s,the time of pre-ignition from 7 s to 6 s,and time of exposure from 8 s to 3 s;② for the determination of C,S and P,high-purity argon(99.999%) with its pressure of 0.30 MPa,should be used;③ a fine grinder should be used in preparing sample in order to make the surface of sample clear and plain,as well as to have clear grain;④ in determination of carbon,temperature of sample should be kept below 40 ℃,and to keep the finess of its grain in its original state;⑤ room temperature of the lab should be kept constant around 25 ℃,and correction of working curves should be made every 8 h;⑥ in determination of sulfur,samples with relatively higher temperature should be cooled to near room temperature before analysis,and at least 3 evenly deposited excitation sites should be taken as well as correction and standardization of the standard working curve should be made.
作者 陈群芝
出处 《理化检验(化学分册)》 CAS CSCD 北大核心 2012年第1期23-26,29,共5页 Physical Testing and Chemical Analysis(Part B:Chemical Analysis)
关键词 直读光谱法 钢铁分析 Direct-reading spectrometry Analysis of iron and steel Carbon Sulfur
  • 相关文献

参考文献3

  • 1孙建国,高键.钢中碳的光电光谱分析[C].山东省理化检验学术交流论文集.济南:山东冶金科学出版社,2002:41-45.
  • 2李美玲,张秀鑫,王辉,陈吉文,王海舟,梁红兵,杨春政,张洪波,郝华强.连铸板坯横截面中心偏析的原位统计分布分析[J].冶金分析,2004,24(z1):66-73. 被引量:6
  • 3GB2222-2006钢的化学分析用试样取样法及成品化学成分允许误差[S].

二级参考文献6

共引文献5

同被引文献39

引证文献9

二级引证文献13

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部