摘要 平面光栅双单色仪是构成光栅衍射效率测试仪的重要组成部分,为了完成光栅衍射效率测试仪的研制,需要对平面光栅双单色仪的光学系统进行设计和模拟。仪器主要由光源、前置单色仪、测量单色仪和探测器组成;结合仪器的实际使用需要,确定了光源、探测器和光路结构,根据仪器的设计要求,分别对前置单色仪和测量单色仪的光学系统进行设计和模拟,给出了各自光学系统的像面点列图和实际光线追迹数据。设计结果保证了仪器光学系统的测量准确性。 The plane grating double monochromator is the important part of the instrument for testing diffraction efficiency of plane grating,and in order to accomplish the research of the instrument,the optical system design and simulation of the plane grating double monochromator was investigated.The instrument mainly consists of light source,front monochromator,testing monochromator and detector,and combined with the practical requirement,the corresponding light source,detector and the structure of the optical path were selected.According to the design requirement,the design and simulation of the optical system of the front monochromator and testing monochromator were done respectively,and the spot diagram of the image surface and the results of real ray trace were given.The analysis showed that in the front monochromator the maximum width of the exit spot and the maximum height of the exit spot were 0.33 and 1.83 mm respectively.On the other hand,in the testing monochromator,the maximum width of the exit spot and the maximum height of the exit spot were 0.66 and 7.27 mm,respectively.Through selecting the size of the exit slit properly,the system can work without luminous flux lost,which guarantees the testing precision of the optical system of the instrument.
出处 《光谱学与光谱分析》 SCIE EI CAS CSCD 北大核心 2012年第3期830-833,共4页 Spectroscopy and Spectral Analysis
基金 国家"十一五"科技支撑计划重大项目(2006BAK03A02) 中国科学院重大科研装备研制项目(YZ200804) 吉林省科技发展计划项目(20070523 20086013) 吉林省重大科技攻关项目(09ZDGG005)资助
关键词 平面光栅 双单色仪 光学设计 结果分析 Plane grating Double monochromator Optical design Results analysis
  • 相关文献

参考文献10

二级参考文献61

共引文献144

同被引文献45

  • 1薛庆生.星载宽波段大气痕量气体临边探测仪光学设计[J].光子学报,2012,41(6):631-637. 被引量:8
  • 2张兴赢,张鹏,方宗义,邱红,李晓静,张艳.应用卫星遥感技术监测大气痕量气体的研究进展[J].气象,2007,33(7):3-14. 被引量:62
  • 3黄煜,王淑荣,张振铎,林冠宇,李福田.用150W氘灯标定200~300nm光谱辐照度[J].光学精密工程,2007,15(8):1215-1219. 被引量:10
  • 4金伟其,胡威捷.辐射度光度与色度及其测量[M].北京:北京理工大学出版社,2009:9-140.
  • 5WANG Zi-jun, CHEN Sheng-bo, YANG Chun-yan, et al. DOAS tomography for the retrieval of trace gas profiles from satellite-based UV-Vis limb spectra[J]. Chinese Optics Letters, 2010, 9(2): 020101-1-020101-4.
  • 6RAULT D. Stratospheric and upper tropospheric aerosol retrieval from limb scatter signals[C]. SPIE, 2007, 6745: 674509-1-674509-12.
  • 7RAULT D F, LUMPE J, EDEN T, et al. The OMPS limb profiler instrument an alternative data analysis and retrieval algorithm[C]. SPIE, 2009, 7474: 74741R-1-74741R-12.
  • 8WANG Chao, SHI Run-he, Zhou Cong, et al. Comparison of SCIAMACHY and AIRS CO2 measurement over China form 2003 to 2005[C]. SPIE, 2011, 8156: 81560N-1-81560N-9.
  • 9LIEWELLYN E J, LIOYD N D, DEGENSTEIN D A, et al. The OSIRIS instrument on the Odin spacecraft[J]. Canada Journal of Physics, 2004, 82: 411-422.
  • 10XUE Qing-sheng, WANG Shu-rong, LU Feng-qin. Aberration-corrected Czerny-Turner imaging spectrometer with a wide spectral region[J]. Applied Optics, 2009, 48(1): 11-16.

引证文献6

二级引证文献26

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部