摘要
结合燃水比控制原理,以绥中发电有限责任公司1 000 MW燃煤机组为例,阐述了超超临界机组燃水比控制的策略,通过对机组运行工况下燃水比控制调节问题的探讨,提出相应的解决方案。
Combined with Fuel-water ratio control theory,taking example of 1 000 MW ultra-supercritical units control in Suizhong power plant,it describes ultra-supercritical unit fired water ratio control strategy,discussing the control adjustment problems of the water-fuel unit under operating conditions,and solution to it.
出处
《东北电力技术》
2012年第1期5-7,共3页
Northeast Electric Power Technology
关键词
超超临界机组
燃水比
中间点温度
调节品质
Ultra-supercritical units
Fuel-water ratio
Mid-point temperature
Adjustment quality