两种消毒液对凯迪康硅橡胶尺寸精度的影响 被引量:3

The effect of two kinds of disinfectant on the size accuracy of ChemomentTM Silicone dental impression material
下载PDF
导出
摘要 目的测试消毒液对凯迪康硅橡胶尺寸精度的影响。方法使用重、轻体成分的加成型硅橡胶采用两次法分别制取同一实验模具的印模,随机平均分为3组,每组15个。对照组:清水冲洗,实验组1:使用2%戊二醛浸泡消毒,实验组2:使用84消毒液浸泡消毒。灌注石膏模型,用游标卡尺测量主模型及石膏模型上各标志点的距离,对测量数据进行统计学分析,用χ2比较所取印模经过浸泡后对水晶牙模复制精度上的差异。结果两种消毒液浸泡的印模与对照组印模在对水晶牙模复制精度上效果相同,三者之间差异无统计学意义。在线性变化率上比较,浸泡消毒液的印模的BC、DE值变化率均比对照组要大,但与原始数据差异无统计学意义。结论凯迪康加成型硅橡胶印模材料使用2%戊二醛溶液和有效氯浓度为0.3%的84消毒液溶液浸泡消毒,不影响其印模精度。 Objective To test the effect of two kinds of disinfectant on the size accuracy of ChemomentTM Silicone dental impression material.Methods Make three groups of addition silicone rubber impression for one and the same master model by two-step technique.The impressions were randomly divided into three groups.1:control group;2:2%alkaline glutaraldehyde;3:84TM disinfectant.Stone models were made of all impressions.Vertical and horizontal dimensions between landmarks on the master and stone models were measured with vernier caliper.Chi-square test was used to compare the size accuracy of all the models.Results The difference of dimensions accuracy of in three groups stone models is no statistical significance.The difference of linear change-rate of three groups stone models is statistical significance,but the difference of dimensions between the experimental groups and master model is no statistical significance.Conclusion ChemomentTM Silicone dental impression material should be sterilized with 2%alkaline glutaraldehyde or 84 disinfectant containing 0.3% chlorine.The two kinds of disinfectant will not effect the accuracy of the addition silicone rubber impression.
出处 《安徽医学》 2012年第1期76-78,共3页 Anhui Medical Journal
关键词 加成型硅橡胶 消毒 精度 Addition silicone rubber impression Disinfectant Accuracy
  • 相关文献

参考文献10

  • 1Powell GL,Runnells RD.The presence and identification of organisms transmitted to dental laboratory.J Prosthet Dent,1990,64 (2):235-237.
  • 2Hasson AK.Dimensional accuracy of 3 silicone dental impression materials.EasternMediterranean Health J,2006,12(5):632-636.
  • 3杜方翀,陈吉华,甘云娜,林玲,成炜,沈焕.五种硅橡胶印模材料对牙冠颈缘复制精度的比较[J].中国美容医学,2007,16(4):501-503. 被引量:11
  • 4柳文娟,李四群,李志安,黄翠.硅橡胶印模材料表面润湿性的研究进展[J].国外医学(口腔医学分册),2003,30(6):464-466. 被引量:10
  • 5Beyerle MP,Hensley DM,Bradley DV,et al.Immersion disinfection of irreversible hydrocolloid impressions with sodium hypochlorite.Part Ⅰ:Microbiology. Int J Prosthodont,1994,7:234-238.
  • 6Walker MP,Rondeau M,Petrie C,et al.Surface quality and long-term dimensional stability of current elastomeric impression materials after disinfection.J Prosthodont,2007,16 (5):343-51.
  • 7邓宏燕,张振庭,邓小虹,孙正,王为农.浸泡消毒对硅橡胶印模三维尺寸稳定性的影响[J].中华口腔医学杂志,2005,40(2):171-171. 被引量:4
  • 8郭翠,张振庭.浸泡消毒对硅橡胶印模表面质量的影响[J].北京口腔医学,2008,16(5):263-265. 被引量:12
  • 9Gordon GE,JohLnson GH,Drennon DG.The effect of trays election on the accuracy of elastomeric impression materials.J Prosthet Dent,1990,63 (1):12-16.
  • 10Wilson HJ.ImPression materials.Br Dent,1988,164:221-223.

二级参考文献41

  • 1邓宏燕,张振庭,邓小虹,孙正,王为农.浸泡消毒对硅橡胶印模三维尺寸稳定性的影响[J].中华口腔医学杂志,2005,40(2):171-171. 被引量:4
  • 2文理衡,刘清辉,周琳.固定修复三种印模法临床效果的对比[J].现代口腔医学杂志,2005,19(2):116-116. 被引量:11
  • 3Centers for Disease Control. Recommended infection control practices for dentistry. MMWR-Recomm-Rep 1993 ,41 ( RR-8 ) : 1-12.
  • 4Hall BD, Naylor WP. Effects of a chemical disinfectant on the physical properties of dental stones . Int J Prosthodont, 2004, 17 ( 1 ) :65-71.
  • 5Johnson GH, Chellis KD, Gordon GE, et al. Dimensional stability and detail reproduction of irreversible hydrocolloid and elastomeric impressions disinfected by immersion. J Prosthte Dent, 1998,79 (4) : 446-453.
  • 6Tan HK, Wolfaardt JF, Hooper PM, et al. Effects of disinfecting irreversible hydrocolloid impressions on the resultant gypsum casts: Part Ⅰ -Surface quality. J Prosthet Dent,1993,69(3) :250-257.
  • 7Revised American Dental Association Specification No. 19 for nonaqueous, elastomeric dental impression materials. J Am Dent Assoc, 1977,94(4) :733-741.
  • 8ISO 4823 for Elastomeric impression materials. International Organization for Standardization (ISO) Technical committee : TC 106/SC 2;2000.
  • 9Council on Dental Materials, Instruments, and Equipment. Council on Dental Therapeutics. Infection control recommendations for the dental office and the dental laboratory. J Am Dent Assoc, 1988,116 (2) :241-248.
  • 10Derrien G, Menn GL Evaluation of detail reproduction for three die materials by using scanning electron microscopy and two-dimensional profilometry. J Prosthet Dent, 1995,74 ( 1 ) : 1-7.

共引文献30

同被引文献498

引证文献3

二级引证文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部