摘要
建立了废水的萃余水相及回收后N,N-二甲基甲酰胺的高效液相色谱检测方法.采用Krornasil-C18色谱柱分离,流动相为甲醇和水(体积比15∶85),紫外检测波长为205 nm.结果表明:DMF的浓度在3.06~38.28 mg/L时与色谱峰面积之间线性关系良好(r=0.999 7),相对标准偏差为1.03%,加标回收率为99.86%~101.09%.该方法简便快速,结果准确,重现性好,可为废水中N,N-二甲基甲酰胺的定量分析及回收提供较好的中控分析方法.
A method for DMF in waste water and organic phase with high performance liquid chromatography(HPLC) was established.HPLC was performed on a Krornasil-C18 column,using methanol and water(15∶85) as mobile phase and the detection wavelength of 205nm.The results show that the calibration curve is linear in the range of 3.06mg/L-38.28mg/L for concentration of DMF(r=0.9997),precision is high,and its relative standard deviation is 1.03%.The recovery DMF is between 99.86%-101.09%.The method is rapid,accurate,reproducible and can be used for quantitative analysis of DMF in wastewater and provided as a good central control analysis method of recycling conditions of wastewater.
出处
《南京师范大学学报(工程技术版)》
CAS
2011年第4期89-92,共4页
Journal of Nanjing Normal University(Engineering and Technology Edition)
基金
江苏省自然科学基金(BK2009409)
南京师范大学"211工程"三期重点学科建设项目
江苏高校优势学科建设工程项目
关键词
高效液相色谱法
DMF
中控分析
high performance liquid chromatography,DMF Wastewater,middle-controlled analysis