摘要 以东华大学图书馆土壤源热泵系统为研究对象,对冬季供热工况的运行特性进行测试,得到了系统的热泵机组制热能效比、综合性能以及输送系数逐时变化情况,数据分析表明,该系统运行情况效果良好,为周边相近地区土壤源热泵的应用提供了数据支持。 With Donghua University Library ground source heat pump (GSHP) system example, the heat pump heating system, energy efficiency, overall performance and transmission and The operating characteristics of heating conditions in winter were test- ed, the heat pump heating performance coefficient (COP) ,combination property and transport coefficit^nt changes along with time were got in this paper. The data analysis indicated that the operating condition of this system was fairly well and it provided the data support for the application of the GSHP in the places of the neighborhoods.
出处 《流体机械》 CSCD 北大核心 2012年第2期72-75,共4页 Fluid Machinery
基金 上海市科学技术委员会资助项目(08DZ1204100)
关键词 土壤源热泵 制热能效比 综合性能 输送系数 GSHP COP combination property transport coefficient
  • 相关文献

参考文献7

  • 1Rawlings R H D and Sykulski J R. Ground heat pumps : A technology review [ C ]. Proc. CIBSE A : Building Serv. Eng. Res. Technol, 1999, 20(3): 119-129.
  • 2Kavanaugh S P, Field test of vertical ground-coupled heat pump in Alabama [ J]. ASHRAR Transactions, 1992, 98(2):607-616.
  • 3Kavanaugh S P, Rafferty K D. Ground-source heat pumps: design of geothermal systems for commercial and institutional buildings [ M ]. American Society of Heating, Refrigerating and Air-Conditioning Engineering, 1997.
  • 4杨卫波,施明恒,陈振乾.土壤源热泵夏季运行特性的实验研究[J].太阳能学报,2007,28(9):1012-1016. 被引量:30
  • 5宋著坤,赵军,李新国,黄涛.地源热泵冬夏两季运行性能分析与实验研究[J].流体机械,2006,34(2):55-59. 被引量:8
  • 6孙建平,王景刚,张子平.地源热泵系统运行特性的分析[J].华北电力大学学报(自然科学版),2004,31(5):52-55. 被引量:9
  • 7徐伟.中国地源热泵发展研究报告2008[D].北京:中国建筑工业出版社,2008:201-211.

二级参考文献22

  • 1赵军,宋德坤,李新国,张春雷.埋地换热器放热工况的现场运行实验研究[J].太阳能学报,2005,26(2):162-165. 被引量:19
  • 2Zeng Heyi,Diao Nairen,Fang Zhaohong.Heat transfer analysis of boreholes in vertical ground heat exchangers[J].International Journal of Heat and Mass Transfer,2003,46(1):4467-4481.
  • 3Burkhard Sanner,Constantine Karytsas,Dimitrios Mendrinos,et al.Current status of ground source heat pumps and underground thermal energy storage in Europe[J].Geothermics,2003,32:579-588.
  • 4Bose J E.Advances in ground source heat pump systems an international overview[A].7th International Energy Agency Heat PumpConference [C].Beijing:2002.313-324.
  • 5Cane R L D,Forgas A.Modeling of ground source heat pump performance [J].ASHRAE Trans.,1991,97 (1):909-925.
  • 6Yavuzturk C,Spitler J D,Rees S J.A short time step response factor model for t Vertical U-Tube Ground Heat Exchangers[J].ASHRAETans.,1999,105 (2):475-485.
  • 7Bose J E, Parker J D. Ground-coupled heat pump research[J]. ASHRAR Transactions, 1983, 89(2): 18-23.
  • 8Bose J E, Parker J D, McQuiston F C. Design/data manual for closed-loop ground-heat pump system[M]. Atlanta(America) : American Society of Heating Refrigerating and Air-Conditioning Engineers, 1985.
  • 9Catan M A, Baxter V D. Optimized ground-coupled heat pump system design for northern climate applications [J]. ASHRAR Transactions, 1985, 91(2B): 1185-1201.
  • 10Mei V C, Baxter V D. Performance of a ground-coupled heat pump with multiple dissimilar U-tube coils in series[J]. ASHRAR Transactions, 1986, 92(2A) : 30-42.

共引文献44

同被引文献29

引证文献4

二级引证文献10

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部