摘要
以东华大学图书馆土壤源热泵系统为研究对象,对冬季供热工况的运行特性进行测试,得到了系统的热泵机组制热能效比、综合性能以及输送系数逐时变化情况,数据分析表明,该系统运行情况效果良好,为周边相近地区土壤源热泵的应用提供了数据支持。
With Donghua University Library ground source heat pump (GSHP) system example, the heat pump heating system, energy efficiency, overall performance and transmission and The operating characteristics of heating conditions in winter were test- ed, the heat pump heating performance coefficient (COP) ,combination property and transport coefficit^nt changes along with time were got in this paper. The data analysis indicated that the operating condition of this system was fairly well and it provided the data support for the application of the GSHP in the places of the neighborhoods.
出处
《流体机械》
CSCD
北大核心
2012年第2期72-75,共4页
Fluid Machinery
基金
上海市科学技术委员会资助项目(08DZ1204100)