期刊文献+

铝丝阵等离子体K壳层辐射区域测量

Measurement of K-shell radiation distribution in aluminum wire array plasma
下载PDF
导出
摘要 采用球面云母晶体,在特定的几何布局下,通过选择适当的设计参数,在1.3 MA脉冲功率装置上获得了Lyα线表征的Z箍缩铝丝阵等离子体K壳层辐射时间积分2维分布。与通常采用的带滤片卡域的时间积分针孔成像相比,避免了由于无法将测量能段准确设定在K壳层辐射谱线所在能区,而造成测量结果偏离真实的K壳层辐射分布的缺点,为模拟计算Z箍缩等离子体辐射输运程序提供了更为精确的校验参数。 The time-integrated two-dimensional distribution of aluminum wire array Z-pinch plasma K-shell radiation which is characterized by Lya line was measured in a 1.3 MA generator, with spherically bent mica crystal in a specific layout of appro priate design parameters. The employment of spherically bent crystal instead of filter can realize accurate setting of measurement energy region and thus effectively improve the measurement accuracy of K-shell radiation distribution. The results presented provide more accurate calibration parameters for the radiation transport codes of Z-pinch plasma.
出处 《强激光与粒子束》 EI CAS CSCD 北大核心 2012年第1期234-238,共5页 High Power Laser and Particle Beams
基金 国家自然科学基金项目(11005095)
关键词 铝丝阵 K壳层辐射 球面晶体 2维成像 aluminum wire array K-shell radiation spherically bent crystal two-dimensional imaging
  • 相关文献

参考文献11

  • 1Apruzese J P, Whitney K G, Davis J, et al. K-shell line ratios and powers for diagnosing cylindrical plasmas of neon, aluminum, argon, and titanium[J]. J Quant Spectrosc Radiat Transf, 1997,57 ( 1 ) : 41-52.
  • 2Grabovski E V, Zukakishvili G G, Nedoseev S L, et al. Roentgenographic investigations of the dynamics and spatial structure of wire-array Z-pinehes[J]. Plasma Phys Rep, 2004,30 (1) : 30-36.
  • 3Pikuz T A, Faenov A Y, Pikuz S A, et al. Bragg X-ray optics for imaging spectroscopy of plasma microsources[J]. J X-ray Sci Technol, 1995,5(3) :323-344.
  • 4Young B K F, Osterheld A L, Price D F, et al. High resolution X-ray spectrometer based on spherically bent crystals for investigations of femtosecond laser plasmas[J].Rev Sci Instrum ,1998,69(12) :4049-4057.
  • 5Pikuz S A, Shelkovenko T A, Chandler K M. et al. X-ray spectroscopy for high energy-density X pinch density and temperature measure ments[J]. Rev Sci Instrum ,2004,75(10) :3666-3674.
  • 6Shelkovenko T A, Pikuz S A, Hammer D A, et al. Use of spherically bent crystals to diagnose wire array Z pinches[J]. Rev Sci Instrum 2004,75(10) :3681-3687.
  • 7Hall G N, Pikuz S A, Shelkovenko T A, et al. Structure of stagnated plasma in aluminum wire array Z pinches[J]. Phys Plasmas ,2006,13 082701.
  • 8Wenger D F, Sinars D B, Rochau G A, et al. Focusing in-chamber spectrometer triplet for high resolution measurements on the Sandia Z facility[J]. Rev Sci Instrum , 2006,77:10F312.
  • 9Sinars D B, Chandler G A, Bailey J E, et al. Measurements of K-shell Ar spectra from Z-pinch dynamic hohlraum experiments made using a focusing spectrometer with spatial resolution[J]. J Quant Spectrosc Radiat Transf, 2006,99(1/3) ,595-603.
  • 10Griem H R. Principles of plasma spectroscopy[M]. Cambridge : Cambridge University Press, 1997 : 54-55.

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部