摘要
从监测结果控制的角度对近10年的土壤中PAEs监测方法进行了探讨,重点比较了索氏萃取柱净化GC/MS、微波萃取柱净化GC、加速溶剂萃取柱净化GC/MS和加速溶剂萃取GPCGC/MS方法的检出限、精密度和准确度。旨在为中国土壤监测方法的建立提供基础支撑,为开展质量控制工作提供评价依据。
The monitoring methods for phthalate esters(PAEs) in soil in recent 10 years was discussed from monitoring results control. The detection limit, precision and accuracy between the four monitoring methods including soxhlet extraction-column purification- GC/MS, microwave extraction-column purification- GC, accelerated solvent extraction-column purification- GC/MS and accelerated solvent extraction - GPC - GC/MS method were compared in this study. This paper aimed to provide basic support for the establishment of soil monitoring method, and offer evaluating basis for the conduct of quality control.
出处
《环境监控与预警》
2012年第1期14-16,23,共4页
Environmental Monitoring and Forewarning
基金
环保公益性行业科研专项项目(200809140)
关键词
土壤
酞酸酯
监测方法
质量控制
soil
phthalate esters
monitoring method
quality control