期刊文献+

异丙酚不同效应室浓度下皮肤电传导与脑电双频指数的比较 被引量:3

Comparison of skin conductance with bispectral index in different effect-site concentrations of propofol
下载PDF
导出
摘要 目的评价异丙酚靶控输注(TCI)时在不同效应室浓度(Ce)下皮肤电传导(SC)与脑电双频指数(BIS)的变化特点。方法择期全麻下行手术患者30例,年龄25~55岁,ASA(Ⅰ~Ⅱ)级,靶控输注异丙酚,设定血浆靶浓度为3μg/mL,在效应室浓度达到3μg/mL后停止靶控;同时记录靶控期间BIS值、SC值、MAP和HR。比较各监测指标在效应室浓度为:0、0.5、1.0、1.5、2.0、2.5和3.0μg/mL时各自的变化差异,以及与Ce的相关性。结果 SC值和BIS随着Ce的增加逐渐变小,MAP和HR无显著性变化;各监测指标与Ce进行相关分析显示,BIS(r=-0.872,P〈0.01)较SC值(r=0.766,P〈0.01)稍高,HR最低(r=0.136,P〈0.05)。当Ce在0-1.5μg/mL时SC与Ce的相关系数(r=-0.852,P〈0.01)较BIS(r=-0.801,P〈0.01)高;当Ce在1.5-3.0μg/mL时,SC与Ce的相关系数(r=-0.791,P〈0.01)较BIS(r=-0.890,P〈0.01)低。结论在异丙酚靶控输注下,BIS与SC较MAP和HR更好的反映了Ce的变化;在Ce为0~1.5μg/mL时,与BIS相比,SC对反映Ce的变化较敏感。 [ Objective ] To evaluate changes of skin conductance (SC) and bispectral index (BIS) during different target effect-site concentrations (Ce) of propofol. [ Methods ] Thirty ASA ( Ⅰ - Ⅱ ) patients aged 25-55 years, were enrolled into this study in general anesthesia for orthopaedics surgery. The exclusion criteria were known contraindications to potential anesthetic drugs, psychoactive medication, neurological disorder or neuropathy and the use of atropine or other anticholinergics in the pre-operative phase. None of the participants received premedication on the day of surgery. BP, ECG, HR and SpO2 were monitored during anesthesia. Anesthesia was induced with target-controlled infusion (TCI) of propofol through the upper extremity venous. Target plasma concentrations (Cp) was defined as 3.0 μg/mL. MAP, HR, BIS and SC values were recorded in the period of time that Ce reached 3.0 μg/mL. Statistical analysis used repeated measurement ANOVA and correlation analysis. [ Results ] With increase of Ce, the val-ue of SC and BIS decreased gradually. The MAP and HR have little change, and they compared the correlation with the Ce, the correlation coefficient of BIS (r =-0.872, P 〈0.01) was higher than SC (r =0.766, P 〈0.01); HR(r =0.136, P 〈0.05) is the lowest correlation coefficient in them. However, when Ce was less than 1.5μg/mL, the correlation co- efficient of SC (r =-0.852, P 〈0.01) was higher than BIS (r =-0.801, P 〈0.01), and SC decreased greatly. When Ce was higher than 1.5 μg/mL, the correlation coefficient of SC (r =-0.791, P 〈0.01) was less than BIS (r =-0.890, P 〈 0.01), and SC decreased slowly, BIS has no such features. [ Conclusion] During TCI of propofol, the value of both SC and BIS continued to reduce with increasing Ce. They reflected better the changes of Ce than MAP and HR. When Ce was less than 1.StLg/mL, compared with BIS, SC had a good sensitivity reflecting change of Ce.
出处 《中国现代医学杂志》 CAS CSCD 北大核心 2012年第1期65-68,共4页 China Journal of Modern Medicine
关键词 异丙酚 脑电双频指数 皮肤电传导 propofol bispectral index skin conductance
  • 相关文献

参考文献2

二级参考文献17

  • 1IselinChavesIA, E1MoalemHE, GanTJ, etal. Changes in the auditory evoked potentials and the bispectral index following propofol or propofol and alfentanil. Anesthesiology, 2000,92:1300-1310.
  • 2Lysakowski C, Durmont L, Pellegrini M, et al. Effects of fentanyl,alfentanil, remifentanil and sufentanil on loss of consciousness and bispectral index during propofol induction of anaesthesia. Br J Anaesth,2001,86: 523-527.
  • 3Milne SE, Troy A, Irwin MG, et al. Relationship between bispectral index, auditory evoked potential index and effect-site EC50 for propofol at two clinical end-points. Br J Anaesth, 2003,90:127-131.
  • 4Struys MM, Jensen EW, Smith W, et al. Performance of the ARXderived auditory evoked potential index as an indicator of anesthetic depth: a comparison with bispectral index and hemodynamic measures during propofol administration. Anesthesiology,2002, 96:803-816.
  • 5Tverskoy M, Fleyshman G, Bachrak L, et al. Effect of bupivacaineinduced spinal block on the hypnotic requirement of propofol.Anaesthesia, 1996,51: 652-653.
  • 6Schraag S, Bothner U, Gajraj R, et al. The performance of electroencephalogram bispectral index and auditory evoked potential index to predict loss of consciousness during propofol infusion. Anesth Analg,1999,89:1311-1315.
  • 7Chernik DA, Gillings D, Laine H, et al. Validity and reliability of the observer's assessment of alertness/sedation scale: study with intravenous midazolam. J Clin Psychopharmacol, 1990, 10: 244-251.
  • 8Swinhoe CF, Peacock JE, Glen JB, et al. Evaluation of the pre-dictive performance of a "Diprifusor" TCI system. Anaesthesia,1998, 53(Suppl) : 61-67.
  • 9Coetzee JF, Glen JB, Wium CA, et al. Pharmacokinetic model selection for target controlled infusions of propofol. Anesthesiology,1995, 82: 1328-1345.
  • 10Struys MM, Smet TD, Depoorter B, et al. Comparison of plasma compartment versus two methods for effect compartment-controlled target-controlled infusion for propofol. Anesthesiology, 2000, 92:399-406.

共引文献53

同被引文献39

  • 1宋青,周飞虎,潘亮,王秀英.脑电双频谱指数在ICU镇静剂使用中的监测作用[J].中国康复理论与实践,2006,12(1):66-67. 被引量:9
  • 2Riker RR,Fraser GL,Simmons LE. Validating the sedation-agitation scale with the bispectral index and visual analog scale in adult ICU patients after cardiac surgery[J].Intensive Care Medicine,2001,(05):853-858.doi:10.1007/s001340100912.
  • 3Greif R,Greenwald S,Schweitzer E. Muscle relaxation does not alter hypnoticlevel during propofol anestesia[J].Anesthesia and Analgesia,2002,(03):604-608.
  • 4Nasraway SA SA Jr,Wu EC,Kelleher RM. How reliable is the Bispectral Index in critically ill patients? A prospective,comparative,single blinded observer study[J].Critical Care Medicine,2002,(30):1483-1487.doi:10.1212/WNL.0b013e3181d2aff9.
  • 5LeBlanc JM,Dasta JF,Kane-Gill SL. Role of the bispectral index in sedation monitoring in the ICU[J].Annals of Pharmacotherapy,2006,(03):490-500.
  • 6CHEN L, WANG M, XIANG H.Prediction of effect-site concentration of sufentanil by dose-response target con- trolled infusion of sufentanil and propofol for analgesic andsedation maintenance in burn dressing changes [ J ]. Burns, 2014,40(3 ) -455-459.
  • 7KAWANO S, OKADA H, IWAMURO M. An effective and safe sedation technique combining target-controlled infu- sion pump with propofol, intravenous pentazocine, and bispectral index monitoring for peroral double-balloon en- doscopy[J]. Digestion, 2015,91(2):112-116.
  • 8SWINHOECF,PEACOCKJE,GLEN J B.Evaluation of the predictive performance of a 'Diprifusor' TCI system [J]. Anaesthesia, 1998,53 ( 1 ) : 61 -70.
  • 9BOIFROS M M, PALANCA B J, MASHOUR G A. Es- timation of the bispectral index by anesthesiologists: an inverse turing test [ J ]. Anesthesiology, 2011,114 ( 5 ) : 1 093- 1 101.
  • 10KASUYA Y, GOVINDA R, RAUCH S. The correlation between bispectral index and observational sedation scale in volunteers sedated with dexmedetomidine and propofol [ J ]. Anesth Analg, 2009,109 (6): 1 811 - 1 815.

引证文献3

二级引证文献11

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部