期刊文献+

CT与磁共振图像融合技术对显示正常内耳结构的应用价值 被引量:2

Value of CT and magnetic resonance imaging fusion in visualization of normal inner ear structures
原文传递
导出
摘要 目的 探讨内耳CT与磁共振成像(MRI)图像融合的可行性以及融合图像对正常内耳结构的显示能力.方法 对20例(40耳)双侧内耳及内听道形态正常的感音神经性耳聋患者行多层螺旋CT(MSCT)和MRI扫描,并应用西门子图像融合软件将CT与MRI图像进行配准、融合,然后半定量评价融合图像对正常内耳和内听道结构的显示能力.结果 CT与MRI融合可有9种融合模式,在不同融合模式的图像中CT不反相+MRI反相对骨迷路显示最清晰;CT反相+MRI不反相、CT反相+MRI伪彩对膜迷路显示最清晰、立体感强;CT不反相+MRI反相、CT与MRI均反相对面神经、听神经及蜗神经显示最清晰、最直观、立体感最强;CT不反相+MRI反相、CT反相+MRI不反相、CT伪彩+MRI反相对蜗孔处蜗神经显示最好.结论 CT与MRI图像可以进行精确配准和融合,不同模式融合图像对内耳不同结构的显示清晰度不同. Objective To explore the feasibility of inner ear CT and magnetic resonance imaging (MRI) fusion and its capacities in visualization of normal inner ear structures.Methods Twenty patients (40 ears) with sensorineural hearing loss (SNHL) and normal anatomy of bilateral inner ears and internal auditory canals underwent MSCT and MRI scanning.The MSCT and MRI images of each patient were fused with Siemens image co- registration software.The fused images were then subjected to semi- quantitative evaluation for their capacities in visualization of normal inner ears and internal auditory canals.Results There were 9 methods for CT-MRI image fusion.Among these,the best performance of clear,stereoscopic and (or) intuitive visualization was achieved with non-reverse CT on reversed MRI images for bony labyrinth,reversed CT on non-reversed MRI or revered CT on pseudo-colored MRI images for membranous labyrinth,non-reversed CT on reversed MRI or reversed CT on reversed MRI images for the facial,acoustic nerve,and vestibular nerves,and non-reversed CT on reversed MRI or reversed CT on non-reversed MRI or pseudocolored CT on non-reversed MRI images for cochlear nerve at the helicotrema.Conclusion The CT and MRI images may be fused with various methods to visualize the inner ear structures in a range of resolutions.
出处 《中华生物医学工程杂志》 CAS 2011年第5期454-457,共4页 Chinese Journal of Biomedical Engineering
基金 湖北省卫生厅科研基金(JX1B057)
关键词 体层摄影术 螺旋计算机 磁共振成像 图像融合 内耳 Tomography, spiral computed Magnetic resonance imaging Image fusion Ear, inner
  • 相关文献

参考文献8

二级参考文献88

  • 1吴劲松,陈衔城,史玉泉,陈爽.Noninvasive three-dimensional computed tomographic angiography in preoperative detection of intracranial arteriovenous malformations[J].Chinese Medical Journal,2000(10):51-56. 被引量:17
  • 2巴本冬,吴晓娟,王磊.多模态医学图像融合技术概述[J].信息技术与信息化,2004(6):28-30. 被引量:8
  • 3刘新军,祝新根.听神经瘤手术治疗的听力保留研究进展[J].中国微侵袭神经外科杂志,2007,12(1):46-48. 被引量:7
  • 4Fortnum H, O'Neill C, Taylor R, et al. The role of magnetic resonance imaging in the identifcation of suspected acoustic neuroma: a systematic review of clinical and cost effectiveness and natural history. Health Technol Assess, 2009, 13: iii-iv, ix-xi, 1-154.
  • 5Denton ER, Holden M, Christ E, et al. The identification of cerebral volume changes in treated growth hormone-deficient adults using serial 3D MRI image processing. J Comput Assist Tomogr, 2000, 24:139-145.
  • 6Groell R, Wiltgen M, Wolf G, et al. Digital image fusion of early and delayed CT scans: how to achieve optimal opacification of vessels and squamous cell carcinomas of the head and neck. AJR, 2002, 178:211-213.
  • 7Flickinger JC, Kondziolka D, Niranjan A, et al. Results of acoustic neuroma radiosurgery: an analysis of 5 years'experience using current methods. Neurosury, 2001,94:1-6.
  • 8[1]Hawkes DJ.Algorithms for radiological image registration and their clinical application.J Anat,1998,193:347
  • 9[2]Hill DL.Medical image registration.Phys Med Biol,2001,46:1
  • 10[3]Maintz JB,Viergever MA.A survey of medical image registration.Med Image Anal,1998,2:1

共引文献121

同被引文献16

引证文献2

二级引证文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部