期刊文献+

Fluid flow and heat transfer characteristics of spiral coiled tube: Effects of Reynolds number and curvature ratio 被引量:4

Fluid flow and heat transfer characteristics of spiral coiled tube: Effects of Reynolds number and curvature ratio
下载PDF
导出
摘要 Numerical analysis was performed to investigate flow and heat transfer characteristics in spiral coiled tube heat exchanger. Radius of curvature of the spiral coiled tube was gradually increased as total rotating angle reached 12π. As the varying radius of curvature became a dominant flow parameter, three-dimensional flow analysis was performed to this flow together with different Reynolds numbers while constant wall heat flux condition was set in thermal field. From the analysis, centrifugal force due to curvature effect is found to have significant role in behavior of pressure drop and heat transfer. The centrifugal force enhances pressure drop and heat transfer to have generally higher values in the spiral coiled tube than those in the straight tube. Even then, friction factor and Nusselt number are found to follow the proportionality with square root of the Dean number. Individual effect of flow parameters of Reynolds number and curvature ratio was investigated and effect of Reynolds number is found to be stronger than that of curvature effect. Numerical analysis was performed to investigate flow and heat transfer characteristics in spiral coiled tube heat exchanger. Radius of curvature of the spiral coiled tube was gradually increased as total rotating angle reached 12n. As the varying radius of curvature became a dominant flow parameter, three-dimensional flow analysis was performed to this flow together with different Reynolds numbers while constant wall heat flux condition was set in thermal field. From the analysis, centrifugal force due to curvature effect is found to have significant role in behavior of pressure drop and heat transfer. The centrifugal force enhances pressure drop and heat transfer to have generally higher values in the spiral coiled tube than those in the straight tube. Even then, friction factor and Nusselt number are found to follow the proportionality with square root of the Dean number. Individual effect of flow parameters of Reynolds number and curvature ratio was investigated and effect of Reynolds number is found to be stronger than that of curvature effect.
机构地区 School of Mechatronics
出处 《Journal of Central South University》 SCIE EI CAS 2012年第2期471-476,共6页 中南大学学报(英文版)
基金 supported by the Second Stage of Brain Korea 21 Projects,Korea
关键词 雷诺数效应 螺旋盘管 流体流动 曲率半径 传热特性 NUSSELT数 曲率效应 Dean数 spiral coiled tube heat exchanger Reynolds number curvature ratio secondary flow friction factor Nusselt number
  • 相关文献

参考文献19

  • 1DEAN W R.Note on the motion of fluid in a curved pipe[J].Philosophical Magazine,1927,4:208-223.
  • 2JANSSEN L A M,HOOGENDOORN C J.Laminar convective heat transfer in helical coiled tubes[J].International Journal of Heatand Mass Transfer,1978,21:1197-1206.
  • 3PRASAD B V S S S,DAS D H,PRABHAKAR A K.Pressure drop, heat transfer and performance of a helically coiled tubularexchanger [J].Heat Recovery Systems and CHP,1989,9:249-256.
  • 4ALI S.Pressure drop correlations for flow through regular helical coil tubes[J].Fluid Dynamics Research,2001,28:295-310.
  • 5PRABHANJAN D G,RAGBAVAN G S V,RENNIE T J.Comparison of heat transfer rates between a straight tube heat exchanger and ahelically coiled heat exchanger[J].International Communications in Heat and Mass Transfer,2002,29:185-191.
  • 6ROSE J W.Heat-transfer coefficients Wilson plot and accuracy of thermal measurements[J].Experimental Thermal and FluidScience, 2004,28:77-86.
  • 7NAPHON P.Thermal performance and pressure drop of the helical-coil heat exchangers with and without helically crimped fins[J].International Communications in Heat and Mass Transfer,2007, 34:321-330.
  • 8NAPHON P,WONGWISES S.A review of flow and heat transfer characteristics in curved tubes[J].Renewable and SustainableEnergy Reviews,2006,10:463-490.
  • 9SHOKOUHMAND H,SALIMPOUR M R,AKHAVAN- BEHABADI M A.Experimental investigation of shell and coiled tube heat exchangersusing Wilson plots[J].International Communications in Heat and Mass Transfer,2008,35:84-92.
  • 10SANTINI L,CIONCOLINI A,LOMBARDI C,RICOTTI M.Two-phase pressure drops in a helically coiled steam generator[J]. International Journal of Heat and Mass Transfer,2008,51: 4926-4939.

同被引文献22