摘要 对直膨式土壤源热泵系统性能系数随影响因素的变化规律进行分析。在热泵系统制热模式下,采用分布参数法建立该系统的稳态数学模型,运用该模型计算热泵系统的性能参数,并在所建直膨式土壤源热泵系统性能试验台上测试该系统的性能。研究结果表明:管壁温度、制热量、性能系数等的计算结果和实验结果较吻合,证明模型基本可靠;随着冷却水流量的增大,热泵系统的制热量和性能系数都会随之增大;随着冷却水入口水温增大,热泵系统的制热量和性能参数都会随之减小;热泵的性能系数在2.8-4.5之间,高于常规的空气源热泵的性能系数。 The changing disciplines of COP(Coefficient of performance) of the direct expansion ground source heat pump system with some factors were analyzed.A distributed parameter method was established for this type of heat pump system,and with this model,the working process of this direct expansion ground source heat pump system was simulated and analyzed.A direct expansion ground source heat pump system test bench was set up and tested.The results of wall temperature,COP,heat-capacity agree well with experimental data,which indicates that the mathematical model is reliable.Heat-capacity and COP of this heat pump system increase when the cooling water flow rate in the tube-in-tube heat exchanger increases;heat-capacity and COP decrease when the temperature of inlet water of the tube-in-tube heat exchanger rises.The COP of the pump system is between 2.8-4.5,and is higher than that of air-source heat pumps.
出处 《中南大学学报(自然科学版)》 EI CAS CSCD 北大核心 2012年第2期738-742,共5页 Journal of Central South University:Science and Technology
基金 国家"十一五"科技支撑项目(2006BAJ04B04)
关键词 传热 制热 地源热泵 制冷剂 heat transfer heating ground source heat pump refrigerant
  • 相关文献

参考文献11

二级参考文献48

  • 1王起霄,刘淑静,汝长海.变频空调的性能研究[J].哈尔滨商业大学学报(自然科学版),2001,17(3):69-71. 被引量:16
  • 2H.L.von库伯 王子介(译).热泵的理论与实践[M].北京:中国建筑工业出版社,1986..
  • 3Tassou S A,Marqunand C J,Wilson D R.Comparison of the performance of capacity controlled and conventional ON/OFF controlled heat pumps[J].Applied Energy,1983,5(4):241-256.
  • 4Vargas J V C.Simulation in transient regime of a heat pump with closed-loop and on-off control[J].International Journal of Refrigeration,1995,18(4):235-243.
  • 5Eckels S J.Evaporation and condensation of HCF-134a and CFC-12 in a smooth tube and a micro-fm tube[J].ASHRAE Trans,1991,97:71-81.
  • 6Sami S M,Tulej P J,Song B.Study of heat and mass characteristics of ternary non-azeotropic refrigerant mixtures inside air/refrigerant enhanced surface tubing[J].ASHRAE Trans,1995,101:1402-1412.
  • 7Slugem K.Enhancement of in-tube condensation of non-azeotropic refrigerant mixture with a micro-fin tube[J].Trans of the JAR,1993,10(1):95-101.
  • 8Masaaki T T O,Hideyaki K.Boiling heat transfer and pressure drop in internal spiral-grooved tubes[J].JSME,1979,22:171-173.
  • 9龚光彩,二十一世纪中国与可持续发展国际会议论文集,1999年
  • 10张国强,中国可持续发展研究会论文集,1999年

共引文献169

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部