摘要2004年6月南非麻醉科医师Miller等发明并推出一种新型喉上通气装置SLIPA(streamlined liner of the pharynx airway),试图改善以往喉罩价格昂贵、医源性交叉感染、咽喉部神经压迫损伤及反流误吸等不足。该通气道由软塑料吹制塑形而成,形如一只人脚,具有类似足尖、足背和足跟等突起,
1Lange M, Smul T, Zimmermann P, et al. The effectiveness and patient comfort of the novel streamlined pharynx airway liner (SLIPA) compared with the conventional laryngeal mask airway in ophthalmic surgery. Anesth Analg, 2007,104 (2) : 431-434.
2Miller DM, Camporota L. Advantages of ProSeal and SLIPA airways over tracheal tubes for gynecological laparoscopies. Can J Anaesth, 2006,53(2) : 188-193.
2Miller DM. A proposed classification and scoring system for supraglottic sealing airways: a brief review. Anesth Analg, 2004,99: 1553-1559.
3Hooshangi H, Wong DT. Brief review: the Cobra Perilaryngeal Airway (CobraPLA) and the Streamlined Liner of Pharyngeal Airway (SLIPA) supraglottic airways. Can J Anaesth, 2008, 55:177-185.
4Jackson KM, Cook TM. Evaluation of four airway training manikins as patient simulators for the insertion of eight types of supraglottic airway devices. Anaesthesia, 2007,62 : 388-393.
5Keller C, Brimacombe J, Bittersohl J, et al. Aspiration and the laryngeal mask airway:three cases and a review of the literature. Br J Anaesth, 2004,93 : 579-582.
6岳云,主译.喉罩麻醉-原理与实践.北京:人民卫生出版社,2006:579-580.
7Wrobel M,Grundmann U,Wilhelm W,et al.Laryngeal tube versus laryngeal mask airway in anaesthetised non-paralysed patients:a comparison of handling and postoperative morbidity.Anaesthesist,2004,53:702-708.
9Puri GD,Hegde HV,Jayant A,et al.Haemodynamie and Bispectral index response to insertion of the Streamlined Liner of the Pharynx Airway(SLIPA):comparison with the laryngeal mask airway.Anaesth Intensive Care,2008,36:404-410.
10Lange M,Smul T.Zimermann P,et al.The effectiveness and patient comfort of the novel streamlined pharynx airway liner (SLIPA) compared with the conventional lryngeal mask airway in ophthalmic surgery.Anesth Analg,2007,104:431-434.
6Kunisawa T, Nagata O, Nagashima M, et al. Dexmedetomi dine suppresses the decrease in blood pressure during anes thetic induction and blunts the cardiovascular response to tra cheal intubation[J]. J Clin Anesth, 2009,21 (3) : 194-199.
7Larijani GE,Cypel D,Gratz I,et al. The efficacy and safe- ty of EMLA Cream for awake fiberoptic endotracheal in- tubation[J]. Anesth Analg, 2000,91 (4) : 1024-1026.
8Jagannathan N,Sohn LE,Chang E,et al. A cohort evalua- tion of the Laryngeal Mask Airway-SupremeTM in children [J]. Pediatr Anesth, 2012,22 (8) : 759-764.
9Abu-Shahwan I, Chowdary K. Ketamine is effective in de- creasing the incidence of emergence agitation in children undergoing dental repair under sevoflurane general anes- thesia[J]. Paediatr Anaesth, 2007,17 (9) : 846-850.
10Puri G D,Hegde H V,Jayant A,et al.Haemodynamic and Bispectral index response to insertion of the Streamlined Liner of the Pharynx Airway(SLIPA?):comparison with the laryngeal mask airway[J].Anaesth Intensive Care,2008,36:404.