期刊文献+

A novel electromagnetic induction detector with a coaxial coil for capillary electrophoresis 被引量:1

A novel electromagnetic induction detector with a coaxial coil for capillary electrophoresis
原文传递
导出
摘要 A novel electromagnetic induction detector with two inductors for CE was described here.The two inductors were used as signal detection and reference,respectively.The parameters affecting the detector performance(including coil turns,detection distance, excitation frequency,voltage,etc.) were optimized.Under the optimum condition,the feasibility of the detector was examined by analyzing inorganic ions.The fabricated detector showed good linear relationship between the response and the analytes concentrations,with a detection limit of 13μmol/L for Na~+(S/N = 3).A variety of advantages,such as simple construction, ease of operation,and considerably universal response,suggested this novel detector a promising application prospect in analytical area. A novel electromagnetic induction detector with two inductors for CE was described here.The two inductors were used as signal detection and reference,respectively.The parameters affecting the detector performance(including coil turns,detection distance, excitation frequency,voltage,etc.) were optimized.Under the optimum condition,the feasibility of the detector was examined by analyzing inorganic ions.The fabricated detector showed good linear relationship between the response and the analytes concentrations,with a detection limit of 13μmol/L for Na~+(S/N = 3).A variety of advantages,such as simple construction, ease of operation,and considerably universal response,suggested this novel detector a promising application prospect in analytical area.
出处 《Chinese Chemical Letters》 SCIE CAS CSCD 2012年第2期201-204,共4页 中国化学快报(英文版)
基金 support from the National Natural Science Foundation of China(Nos20727006 and 21075139)
关键词 CE Electromagnetic induction detection MnCl_2 Coaxial coil CE Electromagnetic induction detection MnCl_2 Coaxial coil
  • 相关文献

参考文献12

  • 1P.Kuban,P.C.Hauser,Lab Chip 8(2008) 1829.
  • 2B.L.Karger,A.Guttman,Electrophoresis 30(2009) S196.
  • 3J.Iqbal,S.A.Levesque,J.Sevigny,et al.Electrophoresis 29(2008) 3685.
  • 4D.Theodorescul,E.Schiffer,H.W.Bauer,et al.Proteomics Clin.Appl.2(2008) 556.
  • 5B.Timischl,K.Dettmer,H.Kaspar,et al.Electrophoresis 29(2008) 2203.
  • 6Y.Tanaka,T.Higashi,R.Rakwal,et al.Electrophoresis 29(2008) 2016.
  • 7A.Zinellu,S.Sotgia,M.F.Usai,et al.Anal.Bioanal.Chem.399(2011) 1815.
  • 8L.Y.Zhang,M.X.Sun,J.Chromatogr.B Analyt.Technol.Biomed.Life Sci.877(2009) 4051.
  • 9S.Han,H.Wang,J.Chromatogr.B Analyt.Technol.Biomed.Life Sci.878(2010) 2901.
  • 10M.Wakayama,N.Aoki,H.Sasaki,et al.Anal.Chem.82(2010) 9967.

同被引文献25

  • 1姜旭淦,陈盛霞.毛细管电泳技术及其在生物分子研究中的应用进展[J].江苏大学学报(医学版),2004,14(5):449-452. 被引量:1
  • 2陈燕,黄泽玉,王雅杰,王苏平,康熙雄.全自动多通道毛细管区带电泳法在血清蛋白分析中的临床应用[J].中华检验医学杂志,2006,29(5):420-423. 被引量:17
  • 3J.'W. Jorgenson, K. D. Lukaes. Anal. Chem., 1981,53:1 298.
  • 4J. W. Jorgenson, K. D. Lukacs. J. Chromatogr ,1981,218: 209.
  • 5S. Hjerten. J. Chromatogr,1983,270: 1.
  • 6S. Terabe,K. Otsuka,IC ichikawa, et al. Anal. Chem., 1984, 56: 111.
  • 7S. Hjerten, M. D. Zhu. J. Chromatogr,1985,346: 265.
  • 8J. H. Knox, I. H. Grant. Miniaturisation in pregsure and electro- endosmotically driven liquid chromatography: Some theoretical con- siderations. Chromatographia, 1987,24( 1 ).
  • 9应正华,陈露.高效毛细管电泳(HPCE)在中药分析中的应用.海峡学,2011,23(2):10.
  • 10Zhaohai Yang, MD, PhD, Carolyn H. Chaffin, Pattye L Easley, Beatrice Thigpen, and Vishnu V.B. Reddy, MD. Prevalence of Elevated HemoglobinA2 Measured by the CAPILLARYS System. Am J Clin Pathol, 2009,131:42-48.

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部