期刊文献+

大型循环水泵流道整流试验研究

Experimental Study on the Rectifier of Flow Channel with Large-scale Circulation Pump
原文传递
导出
摘要 针对某电厂大型循环水泵流道短、落差大、流道转弯多导致吸水前池进流条件恶劣的问题,对原设计流道的水流流态、水泵吸水管内流速分布和水流旋转强度等进行了试验研究。试验结果表明,吸水前池下部主流区存在较强旋度的环流涡、吸水管内存在较强的螺旋流是影响水泵进流的主要原因。采取在吸水室布置胸墙的方式进行整流,给出了优选的胸墙底部高程,实施此措施后提高了泵的可靠性。 The experimental study is carried out for the flow channel of a large-scale circulation pump, the flow pattern, water velocity and flow rotating strength is focused on. It is found that there exists a strong vortex in the lower part of the absorbing well and a spiral flow in the suction pipe, which could be the primary cause to affect the inlet of pump. The safety and reliability measures for the pump is thereafter suggested, the breast wall is used in the water-absorbing room, the elevation of the breast wall is optimized and given.
作者 邵罡北 杨勇
出处 《电力建设》 2012年第3期60-65,共6页 Electric Power Construction
关键词 循环水泵 流道 水流流态 流速分布 水流旋转强度 整流措施 circulation pump flow channel flow regime velocity distribution spin intensity rectification measure
  • 相关文献

参考文献5

二级参考文献17

  • 1南京水利科学研究院.水工模型试验(第二版)[M].北京:水利水电出版社,1985:12-15.
  • 2赵建钧.上海外高桥电厂三期工程(2×1000MW机组)循环水泵房流道物理模型试验研究报告[R].南京:南京水利科学研究院,2006.
  • 3赵建钧,程璐.越南广宁电厂循环水泵房流道物理模型试验研究报告[R].南京:南京水利科学研究院,2006.
  • 4赵建钧,程璐.华电芜湖发电厂一期工程(2×660MW机组)循环水泵房流道物理模型试验研究报告[R].南京:南京水利科学研究院,2006.
  • 5タ一ボ機械協会基凖.ボソブ吸入水槽の模型試驗方法[M].日本:日本工業出版株式会社,2005.
  • 6Hydraulic Institute. American National Standard for Pump Intake Design[ M ]. America: Balkema Publishers, 1998.
  • 7金忠青.N-S方程数值解及紊流模型[M].南京:河海大学出版社,1989.50-54.
  • 8刘超.水泵及水泵站[M].北京:科学技术文献出版社,2002.67-71.
  • 9陈椿庭 姜国干.水工模型试验[M].北京:水利电力出版社,1985,12..
  • 10.GB/T50265297泵站设计规范[M].北京:中国计划出版社,1997..

共引文献9