期刊文献+

锥形束CT在牙体牙髓病诊治中的临床应用 被引量:17

Advances of cone-beam computed tomography for diagnosis and treatment of endodontic problems
原文传递
导出
摘要 锥形束CT(CBCT)作为一种新型高分辨率X线成像系统,因扫描速度快、空间分辨率高、辐射剂量小、图像伪影少等优点,在口腔医学领域获得越来越广泛的应用。本文就CBCT在牙体牙髓病诊治中的应用作一综述。 With the advantages of high resolution, rapid scan speed, low dose eduction, and reduced artifact, Cone-beam computed tomography (CBCT) is being widely used in dental practice. The aim of this article is to review the applications of CBCT in the management of endodontic problems.
出处 《中华口腔医学研究杂志(电子版)》 CAS 2012年第1期57-59,共3页 Chinese Journal of Stomatological Research(Electronic Edition)
关键词 锥形束CT 牙体牙髓病 诊治 Cone-beam computed tomography Endodontics Diagnosis
  • 相关文献

参考文献18

  • 1Kan CH,Richmond S,Palomo JM,et al.Three-dimensional cone beam computerized tomography in orthodontics.J Orthod,2005,32(4):282—293.
  • 2Guerrero ME,Jacobs,Loubele M,et al.State-of-the-art on cone beam CT imaging for preoperative planning of implant placement.Clin Oral Investig,2006,10(1):1-7.
  • 3Hatcher DC.Dial C,Mayorga C.Cone beam cT for pre-surgical assessment of implant sites.J Calif Dent Assoc,2003,31(11):825—833.
  • 4Kobayashi K,Shimoda S,Nakagawa Y,et al.Accuracy in measurement of distance using limited cone—beam computerized tomography.Int J Oral Maxillofac Implants,2004,19(2):228-231.
  • 5Anti Y,Honda K,lwai K,et al.Practical model"3DX"of limited cone—beam X—ray CT for dental use.Int Conger Ser,2001,1230(7):713-718.
  • 6Patel S,Dawood A,Ford TP,et al.The potential applications of cone beam computed tomography in the management of endodontie problems.Int Ended J,2007,40(10):818-830.
  • 7Honda K,Arai Y,lwai K,et al.Fundamental Efficiency of new-style limited—cone-beam CT(3DX).Comparison with Helical CT.J Tomogr,2000,27(4):193-198.
  • 8方冬,赵堃,袁宪顺,张东升.Implagraphy牙颌面锥形束CT与多层螺旋CT的图像质量对比研究[J].中华老年口腔医学杂志,2008,6(4):226-229. 被引量:38
  • 9Hashimoto K,Anrai Y,Iwai K,et al.A comparison of a new limited cone beam computed tomography machine for dental use with a multidetector roW helieal CT machine.Oral Surg Oral Med Oral Pathol Oral Radial Ended,2003,95(3):371—377.
  • 10Iwai K,Anti Y,Hashimoto K,et al.Estimation of effective dose from limited cone beam X-ray CT examination.歯科放射線,2000,40(4):251—259.

二级参考文献3

  • 1[1]Wiujam C,Allan G,Predag S.Clinical Applications of Cone-Beam Computed Tomography in Dental Practice[J].J Can Dent Assoc 2006,72(1):75-80
  • 2[3]Hashimoto K,Kawashima S,Araki M.Comparison of image performance betweerl cone-beam computed tomography for dental use and four-row multidetector helical CT[J].Journal of Oral Science 2006,48(1):27-34
  • 3崔敏毅.口腔颌面部CT三维技术的应用与进展[J].国际口腔医学杂志,2004,32(S1):83-85. 被引量:7

共引文献37

同被引文献161

引证文献17

二级引证文献121

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部