期刊文献+

基于弧状电极传感器的气/水两相流参数测量系统设计

Design of gas/liquid two-phase flow parameters measurement system based on concave-shaped electrode sensor
下载PDF
导出
摘要 气/水两相流流动参数的检测对工业过程的控制和优化有重要意义,相含率作为一个重要参数直接影响到两相流建模的精度。为测量两相流相含率参数设计了弧状电极电导传感器测量系统,通过对气/水两相流典型流型的物理模拟研究了相含率与测量电压之间的关系。实验结果表明:弧状电极电导传感器的液相相含率与测量电压存在很好的线性关系,为两相流动态实验参数测量提供了依据。 Measurement of gas/liquid two-phase flow parameters is of great importance to the control and optimization of industrial process. The precision of two-phase flow modeling is directly affected by the component fraction. A measurement system based on concave-shaped electrode conductance sensor is designed to measure the fraction in two-phase flow. Static calibration of typical flow pattern simulation shows that relationship between liquid fraction and measuring voltage is linearly related in gas/liquid two-phase flow. It provides basis for dynamic experimental measurement.
作者 施艳艳 董峰
出处 《传感器与微系统》 CSCD 北大核心 2012年第3期122-125,共4页 Transducer and Microsystem Technologies
基金 国家自然科学基金资助项目(50776063) 天津市应用基础及前沿技术研究计划项目(11JCZDJC22500 11JCYBJC06700)
关键词 参数测量系统 电极传感器 参数设计 两相流 电导传感器 测量电压 动态实验 sensor concave-shaped electrode gas/liquid two-phase flow component fraction
  • 相关文献

参考文献7

  • 1Hewitt G F.Measurement of two phase flow parameters[M].Lon-don:Academic Press,1978.
  • 2Coney M W E.The theory and application of conductance probesfor the measurement of liquid film thickness in two-phase flow[J].Journal of Physics E:Scientific Instruments,1973,6:903-910.
  • 3Panagiotopoulos N,Lucas G P.Simulation of a local four-sensorconductance probe using a rotating dual-sensor probe[J].Mea-surement Science and Technology,2007,18(8):2563-2569.
  • 4Dong F,Jiang Z X,Qiao X T,et al.Application of electrical resis-tance tomography to two-phase pipe flow parameters measure-ment[J].Flow Measurement and Instrumentation,2003,14(4/5):183-192.
  • 5Fossa M.Intermittent flow parameters from void fraction analy-sis[J].Flow Measurement and Instrumentation,2003,14(4/5):161-168.
  • 6Costigan G,Whalley P B.Slug flow regime identification from dy-namic void fraction measurement in vertical air-water flows[J].International Journal of Multiphase Flow,1997,23(2):263-282.
  • 7Andreussi P,Donfrancesco A D,Messia M.An impedance methodfor the measurement of liquid hold-up in two-phase flow[J].In-ternational Journal of Multiphase Flow,1988,14(6):777-785.