期刊文献+

插入式接触电阻测量夹头的研制

The Development of the Plug-in Clip for Contact Resistance Measuring
下载PDF
导出
摘要 由于环网柜结构的原因,传统接触电阻测量夹头不适用于环网柜接触电阻的测量。分析了使用传统接触电阻测量夹头对环网柜进行接触电阻测量方法的缺点,介绍了在此基础上研制的插入式接触电阻测量夹头,通过在现场对环网柜进行接触电阻的测量,证明其具有很好测量效果。 Traditional plug-in clip for contact resistance measurement is unsuitable to contact resistance measur- ing of ring main unit due to the unit structure. The shortcomings of the traditional measurement is analyzed, the developed plug-in clip for contact resistance measuring is described, through the on site measurement for contact resistance of ring main unit proves the new approach has good efficiency.
出处 《供用电》 2012年第1期66-68,共3页 Distribution & Utilization
关键词 环网柜 插入式接触电阻测量夹头 接触电阻 ring main unit plug-in contact resistance measuring clip contact resistance
  • 相关文献

参考文献3

二级参考文献5

  • 1Bo Zhang, Rong Zeng, Jinliang He, etc. Novel measurement system for grounding impedance of substations and power plants[J]. Proceedings of International Conference on Power System Technology, Vol. 3, Dec 2000: 1389-1394.
  • 2Ruifeng Huang, Bo Zhang, I.in I.i. A novel measurement system for substation grounding resistance [J]. CEEm'2003, Nov. 4-7, 2003, Hangzhou, China: 571-572.
  • 3何仰赞 等.电力系统分析[M].武汉:华中理工大学出版社,1995..
  • 4魏畅,傅坚,金之俭,王丰华.接地网阴极保护散流电位分布计算[J].电工技术,2008(8):22-24. 被引量:2
  • 5徐涛,李媛.35kV电阻接地系统接地故障分析与保护措施[J].供用电,2009,26(1):42-44. 被引量:15