摘要
由充实水柱长度计算消防水枪喷嘴压力的常见方法有两种,通过比较、分析讨论,发现这两种方法的计算过程和结果均存在着差异,实际运用时应注意各自的适用范围。
There are two usual methods for computing the pressure of fire nozzles from the spraying spout, and the characteristics of both are different. By comparison and discussion, the computing processions and results of two methods are contrasted and analyzed.
出处
《武警学院学报》
2012年第2期17-19,共3页
Journal of the Armed Police Academy
关键词
消防水枪
喷嘴压力
计算方法
对比
fire nozzles
pressure
computing method
comparison