摘要
从汽车火灾特点出发提出了初起火灾时所需保护面积、泡沫喷淋灭火分区,灭火用喷水量和泡沫混合液流量以及泡沫喷淋管网和比例混合器设置方案。
This paper puts forwards a planning for fire fighting in underground garages based on the auto fire characteristics in terms of desired protection area at the beginning of the fire, foam spray partitions, fire extinguishing spray quantity and mixed foam liquid flow rate and spray foam shower pipes.
出处
《武警学院学报》
2012年第2期37-39,共3页
Journal of the Armed Police Academy
关键词
汽车
火灾特点
最小喷水保护面积
泡沫喷淋灭火分区
管网设置
automobile
fire characteristics
minimum water protection area
foam spray fire extinguishing partition
setting of pipe network