高温中植筋胶拉伸抗剪强度试验研究 被引量:2

Experimental Study on the Shear Strength of Anchorage Adhesive under High Temperature
下载PDF
导出
摘要 为了研究高温中植筋胶的拉伸抗剪强度,进行了57个植筋试件在不同温度下的拉拔试验。试验温度共11个,温度范围为25~350℃。采用电炉加热升温,当到达设定温度后立即进行拉拔实验,每个温度下做5组试件。试验中量测电炉温度,植筋试件温度,植筋滑移和拉拔力。试验结果表明:随着温度升高,植筋胶的拉伸抗剪强度显著下降,当温度高于350℃后,植筋胶基本丧失承载力,约为常温下的4%左右。 To study the shear strength of anchorage adhesive under high temperature,57 specimens were tested.The test temperature ranges from 25℃to 350℃.The specimens were heated by the electric furnace. When heated to the fixed temperature,the specimen was tested.Five specimens were tested in each temperature.In the test,records were made on the furnace temperature,specimen temperature,slip and the force.The test results show that the shear strength decreases with temperature increasing,and the shear strength is about 4%of that in the ambient temperature when the temperature is above 350℃.
出处 《防灾减灾工程学报》 CSCD 北大核心 2012年第1期56-59,76,共5页 Journal of Disaster Prevention and Mitigation Engineering
基金 国家自然科学基金项目(50778134)资助
关键词 高温 植筋胶 拉伸抗剪强度 high temperature post-installed rebar shear strength
  • 相关文献

参考文献6

二级参考文献22

  • 1李平先,赵国藩,张雷顺.新老混凝土粘结面的抗冻融劈拉性能试验研究[J].土木工程学报,2006,39(4):20-25. 被引量:17
  • 2四川省建筑科学研究院、GB50367—2006混凝土结构加固设计规范[S].北京:中国建筑工业出版社,2006.
  • 3中国建筑科学研究院.JGJ145—2004混凝土结构后锚固技术规程[S].北京:中国建筑工业出版社,2005.
  • 4Walter E, Meier P. The Use of Mechanical Dowels as Bond Elements Between Young and Old Concrete: Adherence of Young and Old Concrete[M]. Aedificatio:Verlag, 1994.
  • 5中华人民共和国建筑部.GB/T50081--2002普通混凝土力学性能试验方法标准[s].北京:中国建筑工业出版社,2003.
  • 6CECS25:90.混凝土结构加固技术规范[S].[S].,..
  • 7中华人民共和国建设部.混凝土结构设计规范[S].北京:中国建筑出版社,2002..
  • 8GB50367-2006,混凝土结构加固设计规范[S].
  • 9中华人民共和国建设部.混凝土结构加固技术规范[S].北京:中国建筑工业出版社,1990.
  • 10闫玉红.高温对钢筋混凝土结构植筋锚固性能影响的研究[D].徐州:中国矿业大学建筑工程学院,2005.

共引文献35

同被引文献11

引证文献2

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部