分析连云港港区供水管道漏损的主要原因,并针对该港区采用混合石料填筑形成陆域的特点,从选材、施工、使用管理等方面,提出防治措施。
The main reasons of leaking damage of water supply pipe at Lianyungang Port Area are analyzed. In accordance with the characteristics that the land area is formed by adopting mixed rock filling, the preventive measures are put forward from the aspects of material selection, construction and application management, etc.