期刊文献+

季节性蓄存空气热能的地源热泵空调系统模拟 被引量:10

Simulation on Ground Source Heat Pump System Combined with Seasonal Air Thermal Energy Storage
下载PDF
导出
摘要 针对寒冷地区长期应用地源热泵系统出现的热平衡问题,提出了季节性蓄存环境空气热能的地源热泵供暖空调系统.介绍了该系统的组成及运行模式,建立了系统中各部分的数学模型,确定了系统的运行控制策略,并在此基础上,以哈尔滨地区某办公建筑为对象进行了瞬态数值模拟.由模拟结果可知,该系统能够保持土壤温度场以年为周期的热平衡,全年供暖空调平均性能系数为2.44,与燃煤锅炉供暖和分体空调供冷方案相比,该系统节能率为22.3%. Regarding the problem of ground heat balance in cold area,a ground source heat pump system which can seasonally accumulate environmental air thermal energy was presented.The components and operation modes of the system were introduced,and the control strategy of system operation was determined through setting up the mathematic model of each system section.Based on the mathematic model and control strategy,the transient numerical simulation was carried out for an office building in Harbin.The simulation results show that the ground source heat pump system can retain thermal balance of the soil temperature field over an one year cycle.The average coefficient of performance was calculated to be 2.44.Compared with that of the coal-fired heating and air conditioning,the system energy-saving rate is 22.3%.
出处 《东北大学学报(自然科学版)》 EI CAS CSCD 北大核心 2012年第3期439-443,共5页 Journal of Northeastern University(Natural Science)
基金 北京市"供热 供燃气 通风及空调重点实验室"开放课题(KF201003)
关键词 土壤热平衡 地源热泵 季节性蓄存空气热能 数值模拟 性能系数 ground heat balance ground source heat pump seasonal air thermal energy storage numerical simulation coefficient of performance(COP)
  • 相关文献

参考文献7

  • 1倪龙,唐青松,李安民,马鑫,马最良.带辅助热源的地源热泵设计负荷比分析[J].制冷学报,2010,31(5):18-23. 被引量:22
  • 2董菲,倪龙,姚杨,姜益强,马最良.浅层岩土蓄能加浅层地温能才是地源热泵可持续利用的低温热源[J].暖通空调,2009,39(2):70-72. 被引量:13
  • 3Wang X,Zheng M Y,Zhang W Y,et al.Experimentalstudy of a solar-assisted ground-coupled heat pump system withsolar seasonal thermal storage in severe cold areas[J].Energyand Buildings,2010,42(11):2104-2110.
  • 4Wang H J,Qi C Y,Wang E Y,et al.A case study ofunderground thermal storage in a solar-ground coupled heatpump system for residential buildings[J].Renewable Energy,2009,34(1):307-314.
  • 5Wang H J,Qi C Y.Performance study of undergroundthermal storage in a solar-ground coupled heat pump systemfor residential buildings[J].Energy and Buildings,2008,40(7):1278-1286.
  • 6Wang F,Zheng M Y,Shao J P,et al.Simulation ofembedded heat exchangers of solar aided ground source heatpump system[J].Journal of Central South University ofTechnology,2008,15(S2):261-266.
  • 7Trillat-Berdal V,Souyri B,Fraisse G.Experimental study ofa ground-coupled heat pump combined with thermal solarcollectors[J].Energy and Buildings,2006,38(12):1477-1484.

二级参考文献24

  • 1黄武刚,郭旭晖,黄丽娟,程婷婷.某公共建筑闭式冷却塔辅助冷却的土壤源热泵系统设计[J].铁道标准设计,2008,28(S1):81-84. 被引量:2
  • 2倪龙,荣莉,马最良.含水层储能的研究历史及未来[J].建筑热能通风空调,2007,26(1):18-24. 被引量:11
  • 3汪训昌.关于发展地源热泵系统的若干思考[J].暖通空调,2007,37(3):38-43. 被引量:55
  • 4韩再生 李宁波 冉伟彦.浅层地热能有关问题.地源热泵,2008,(21):28-32.
  • 5中国建筑科学研究院.GB50336-2005地源热泵系统工程技术规范[S].北京:中国建筑工业出版社,2005
  • 6马最良,姚杨,姜益强.暖通空调热泵技术[M].北京:中国建筑工业出版社,2008
  • 7莫肯逊 H P.用地热作热泵运转和反应[C]//陆亚俊,译.第15届国际制冷大会论文译丛(上册),1981
  • 8李芝芳.224户住宅利用太阳能与地热采暖.国外建筑文摘,1984,(2):9-10.
  • 9艾肯霍尔斯特 H.热泵(第四卷)-电动热泵的安装、运转和保养[M].北京:机械工业出版社,1990
  • 10陈建平,贾宏刚.北京市浅层地温(热)资源利用情况与相关规定介绍[C]//地温资源与地源热泵技术应用论文集(第二集).西安:地质出版社,2008:8-13.