期刊文献+

Membrane preconcentration of iron in seawater samples and on-site determination in spectrophotometry 被引量:9

Membrane preconcentration of iron in seawater samples and on-site determination in spectrophotometry
下载PDF
导出
摘要 A novel method for on-site determination of trace iron was developed using membrane preconcentration and spectrophotometric detection. Fe(Ⅱ)-ferrozine complex was reacted with cetyltrimethylammonium bromide (CTAB) to form a Fe(Ⅱ)-ferrozine-CTAB paired compound, which was collected on a membrane by filtration under vacuum. The membrane was immersed in 2 mL of ethanol-nitric acid and the absorbance of the solution measured for quantitative analysis. Various factors affecting the iron collection and determination were investigated. With different sample preconcentration volumes, the range of determination was broadened to 0.5-120 g/L. The detection limit of this method reached 0.19 g/L and the recoveries were between 97.2 and 109% when the concentration enrichment was about 45. The relative standard deviation (n = 7) was 1.9% for samples containing 10 g/L Fe. Twelve seawater samples were analyzed on-site using the proposed method, and two were also analyzed in inductively coupled plasma mass spectrometry. No significant difference was shown between the two methods by the Student's t-test. The method has also been used on-site for iron enrichment experiments with phytoplankton and concluded to be simple, accurate and inexpensive. A novel method for on-site determination of trace iron was developed using membrane preconcentration and spectrophotometric detection. Fe(II)-ferrozine complex was reacted with cetyltrimethylammonium bromide (CTAB) to form a Fe(II)-ferrozine-CTAB paired compound, which was collected on a membrane by filtration under vacuum. The membrane was immersed in 2 mL of ethanol-nitric acid and the absorbance of the solution measured for quantitative analysis. Various factors affecting the iron collection and determination were investigated. With different sample preconcentration volumes, the range of determination was broadened to 0.5-120 ~tg/L. The detection limit of this method reached 0.19 ktg/L and the recoveries were between 97.2 and 109% when the concentration enrichment was about 45. The relative standard deviation (n = 7) was 1.9% for samples containing 10 ~g/L Fe. Twelve seawater samples were analyzed on-site using the proposed method, and two were also analyzed in inductively coupled plasma mass spectrometry. No significant difference was shown between the two methods by the Student's t-test. The method has also been used on-site for iron enrichment experiments with phytoplankton and concluded to be simple, accurate and inexpensive.
出处 《Chinese Journal of Oceanology and Limnology》 SCIE CAS CSCD 2012年第2期315-320,共6页 中国海洋湖沼学报(英文版)
基金 Supported by State Key Laboratory of Marine Environmental Science(MEL)Funds(No.MELRI1001)
  • 相关文献

参考文献23

  • 1Aydin F A, Soylak M. 2010. Separation, preconcentraion and inductively coupled plasma-mass spectrometric determination of thorium(IV), titanium(IV), iron(III), lead(II) and chromium(III) on 2-nitroso-l-naphthol impregnated MCI GEL CHP20P resin. J. Hazard. Mater., 173(1-3): 669-674.
  • 2Blain S, Treguer P. 1995. Iron(II) and iron(III) determination in sea water at the nanomolar level with selective on-line preconcentration and spectrophotometric determination. Anal. Chim. Acta., 308(1-3): 425-432.
  • 3Bowie A R, Achterberg E P, Blain S, Boye M, Croot P L, de Baar H J W, Laan P, Sarthou G, Worsfold P J. 2001. Shipboard analytical intercomparison of dissolved iron in surface waters along a north-south transect of the Atlantic Ocean. Mar. Chem., 84(1-2): 19-34.
  • 4Bowie A R, Sedwick P N, Worsfold R 2004. Analytical intercomparison between flow injection- chemiluminescence and flow inj ection-spectrophotometry for the determination of picomolar concentrations of iron in seawater. Limnol. Oceanogr. Methods, 2(2): 42-54.
  • 5Chen Y, Ding C M, Zhou T Z, Qi D Y. 1999. Organic solvent-soluble membrane filters for the preconcentration and spectrophotometric determination of iron(II) traces in water with Ferrozine. Anal. Chem., 363(1): 119-120.
  • 6Giokas D L, Paleologos E K, Karayannis M I. 2002. Speciation of Fe(II) and Fe(III) by the modified ferrozine method, FIA-spectrophotometry, and flame AAS after cloud-point extraction. Anal. Bioanal. Chem., 373(4): 237-243.
  • 7Gledhill M, van den Berg C M G. 1995. Measurement of the redox speciation of iron in seawater by catalytic cathodic stripping voltammetry. Mar. Chem., 50(1-4): 51-61.
  • 8Hirata S,-Yoshihara H, Aihara M. 1999. Determination of iron(II) and total iron in environmental water samples by flow injection analysis with column preconcentration of chelating resin functionalized with Nhydroxyethylethylenediamine ligands and chemiluminescence detection. Talanta, 49(5): 1 059- 1 067.
  • 9Huang Y M, Yuan D X, Ma J, Zhang M, Chen G H. 2009. Rapid speciation of trace iron in rainwater by reverse flow injection analysis coupled to a long path length liquid waveguide capillary cell and spectrophotometric detection. Microchim Acta, 166(3): 221-228.
  • 10Ihara K, Hasegawa S, Naito K. 2003. Collection of iron(III) from homogeneous aqueous solutions on membrane filters using chromazurol B with triton X-100. Anal. Sci., 19(2): 265-268.

同被引文献123

引证文献9

二级引证文献39

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部