摘要
根据 17片具有分段灌注施工接缝的 PPC模型梁的试验结果 ,提出了分段施工湿接缝混凝土抗拉强度降低系数的建议值 ,可供 PC。
Based on the results of 17 tested PPC model beams with cast\|in\|place joints,the tensile strength reduction factors of concrete at the joints are proposed,which may be used in the design of PC,PPC segmental girders.
出处
《桥梁建设》
EI
CSCD
北大核心
2000年第1期6-8,共3页
Bridge Construction
关键词
预应力混凝土梁
接缝
抗拉强度
模型试验
施工
partial prestressed concrete girder,prestressed concrete girder,joint,tensile strength,factor, model test