摘要
基料-滤层利用数码可视化跟踪技术、计算机信息实时处理技术和土体变形无标点量测技术,对宽级配基料-滤层系统进行了渗透室内模型试验。探讨了滤层准则的适用性,研究了不同滤层厚度和加压速率对管涌发生发展的影响。结果表明:传统太沙基滤层准则不适用于宽级配砂土,建议采用可移动颗粒中的d_(85s)。进行滤层准则设计;增加滤层厚度可提高系统的抗渗透破坏能力,但提高滤层厚度对提高整个系统抵抗渗透能力作用不大;水力梯度增加较快不利于系统的稳定。
By using visual tracing techniques, real-time digital process techniques and non-target measuring techniques,the lab model tests on base soil-filter of broadly graded sandy soil were carried out. The applicability of the filter-layer standard has been discussed; different filter layer thickness and compression rate on piping development influence has invested. The resuits proved that: the traditional Terzaghi filter guideline is improper for broadl graded sand, d85 of moving particles can be used in the design guideline; Increasing filter layer thickness could improve that the system of the seepage failure, but the system penetration ability only improved a little; hydraulic gradient increases faster is not conducive to the stability of the system.
出处
《岩土工程技术》
2012年第1期1-5,共5页
Geotechnical Engineering Technique
基金
国家自然科学基金资助项目(50379037)
关键词
管涌
宽级配砂土
基料一滤层
模型试验
piping
broadly graded sandy soil
base soil-filter
model testing