摘要
目的:建立聚丙烯输液瓶中抗氧剂1010、抗氧剂330、抗氧剂1076、抗氧剂168的含量测定方法。方法:采用Venusil MPC18色谱柱(5μm,250 mm×4.6 mm);流动相:甲醇(100%);流速1.0 mL.min-1;柱温25℃;检测波长为274 nm。结果:抗氧剂1010、抗氧剂330、抗氧剂1076、抗氧剂168分别在0.1029~5.145 mg.mL-1、0.1065~5.325 mg.mL-1、0.1034~5.147 mg.mL-1和0.1040~5.200 mg.mL-1范围内线性关系良好,相关系数均为0.999。聚丙烯输液瓶提取方法中的抗氧剂1010、抗氧剂330、抗氧剂1076、抗氧剂168的平均回收率(n=9)分别为101.8%(RSD=1.6%),99.4%(RSD=1.5%)、88.5%(RSD=4.5%)及86.5%(RSD=5.3%)。结论:该方法灵敏快速,操作简便,重复性好,可用于聚丙烯输液瓶中抗氧剂的质量控制。
Objective: To establish a method for determination of antioxidants 1010,antioxidant 1076,antioxidant 168 and antioxidant 330 in polypropylene infusion bottles.Methods: The Venusil MP C18 analytical column(5 μm,250 mm×4.6 mm)was adopted with the mobile phase of methanol at a flow rate of 1.0 mL·min-1.The column temperature was at 25 ℃.The detection wavelength was at 274 nm.Results: The method had good linear relationship within the range 0.1029-5.145 mg·mL-1,0.1065-5.325 mg·mL-1,0.1034-5.147 mg·mL-1and 0.1040-5.200 mg·mL-1 for antioxidant 1010,antioxidant 1076,antioxidant 168 and antioxidant 330,respectively,with the correlation coefficients of all 0.999.The average recoveries of the four ingredients were 101.8%(RSD=1.6%),99.4%(RSD=1.5%),88.5%(RSD=4.5%)and 86.5%(RSD=5.3%),correspondingly.Conclusion:The method is fast rapid,convenient,accurate and can be used for quality control of antioxidants in polypropylene infusion bottles.
出处
《药物分析杂志》
CAS
CSCD
北大核心
2012年第3期416-418,433,共4页
Chinese Journal of Pharmaceutical Analysis
关键词
药品包装材料
聚丙烯输液瓶
质量控制
抗氧剂
高效液相色谱
相容性试验基础
chemicals packaging materials
polypropylene infusion bottles
quality control
antioxidant
HPLC
compatibility tests basis