135MW机组凝汽器新型酸洗工艺的实施 被引量:1

Implementation of the new type of acid pickle process of condenser unit 135 MW
下载PDF
导出
摘要 新疆某发电有限责任公司2号机组凝汽器不锈钢管结垢严重,凝汽器端差升高,机组效率下降,煤耗上升。采用新型酸洗工艺,选取硝酸复合药剂酸洗后,凝汽器不锈钢管内垢类被完全清除,端差明显降低,由洗前的11℃下降到5℃以下。清洗后换热效果得以改善,煤耗降低,经济效益明显。 The scale formation inside stainless steel tubes, at condenser unit Ⅱ in a Xinjiang Electric Power Co., Ltd., was very serious in the past, which raised the terminal temperature difference of the condenser, reduced the working efficiency of the unit and increased the coal consumption. After having adopted acid pickling with nitric acid composite chemicals ,the scale inside stainless steel tubes can be removed thoroughly ,terminal temperature difference declined obviously from 11℃ to below 5 ℃, heat exchange efficiency improved, coal consumption declined and economic benefit increased noticeably.
出处 《工业水处理》 CAS CSCD 北大核心 2012年第3期90-92,共3页 Industrial Water Treatment
关键词 凝汽器 端差 新型酸洗工艺 condenser terminal temperature difference new type of acid pickling technology