摘要
研究Al/Si摩尔比及制备工艺对聚硅氯化铝(PASC)混凝效果的影响,比较PASC和聚合氯化铝(PAC)的混凝效果.结果表明,PASC较PAC混凝效果好.Al/Si摩尔比和制备工艺对PASC的混凝效果有影响.用共聚法制备的PASC(共),Al/Si摩尔比降低,其混凝效果提高,但复合法制备的PASC(复),Al/Si摩尔比过高或过低,均不利于其混凝效果的提高,PASC(共)的混凝效果稍优于PASC(复)的混凝效果.
The effect of Al/Si molar ratio and the preparation technique on the coagulation of polyaluminum silicate chloride (PASC) was studied, and the coagulation efficiency of PASC was also compared with that of polyaluminum chloride (PAC) by jar test. The experimental results show that PASC is characterized by having better coagulation efficiency, compared with PAC. The PASC prepared by copolymerization technique give a little better coagulating effect than PASC prepared by composite technique under the same Al/Si molar ratio. For the PASC prepared by copolymerization technique, in the range of Al/Si=5~15, the less the Al/Si molar ratio, the better the coagulation efficiency. For the PASC prepared by composite technique, however, the PASC with molar ratio of Al/Si=10 gives best coagulation efficiency.
出处
《环境科学》
EI
CAS
CSCD
北大核心
2000年第2期46-49,共4页
Environmental Science
基金
国家自然科学基金!资助项目
国家"九五"科技攻关项目!96-909-03-02
关键词
聚硅氯化铝
混凝剂
混凝效果
polyaluminum silicate chloride (PASC), coagulant, coagulation.