摘要
目的:目的探讨注射用头孢替唑钠的细菌内毒素定量分析法。方法:用2005年版《中国药典(二部)》中的动态浊度法。结果:供试品稀释40倍可以排除干扰,回收率:50%-200%范围内,试验结果与家兔升温法的一致。结论:用动态浊度法测定头孢替唑钠注射液的细菌毒素含量准确有效。
Objective: To study the interference of Coftezole sodium for Injection in bacterial endotoxin test and to establish the assay method of bacterial endotoxin by dynamic turbidimetry. Methods:Interfering tests for bacterial endotoxin test were used according to China Pharmacopoeia(edition 2005 ). Results:1:40 solution of Coftezole sodium for Injection showed no inference in the test,and the endotion recovery rate was more than 50% and less than 200%. Conclusion:Dynamic turbidimetric assay method can be used accurately and effectively to determine quantitively bacterial endotoxin for Coftezole sodium for Injection.
出处
《黑龙江医药》
CAS
2012年第1期8-9,共2页
Heilongjiang Medicine journal
关键词
动态浊度法
头孢替唑钠注射液
内毒素:干扰试验
dynamic turbidimetric assay
Coftezole sodium for Injection
bacterial endotoxin
interfering test