期刊文献+

室内火灾均一温度假设实验研究 被引量:2

Experimental researches on the homogeneous temperature assumption in compartment fires
下载PDF
导出
摘要 通过小规模火灾实验,对多点温度进行统计分析。结果表明,在轰燃发生前和轰燃发生一段时间后,室内温度均一性较好,发生轰燃时,均一温度假设不成立。在此基础上提出温度分布均一性指数量化温度分布均一化程度,并认为其最小值对应的时间是轰燃发生时间。 By small scale fire experiments, temperature at several points was statistically analyzed. Results showed that before and after the flashover, the temperature in the room is homogeneous, but when there is flashover, the homogeneous temperature assumption doesn't hold. A homogeneity index was pro posed to quantify the homogeneity of indoor temperature, and it was believed that when the index takes the minimum, the flash-over happens.
出处 《消防科学与技术》 CAS 北大核心 2012年第3期239-242,共4页 Fire Science and Technology
关键词 室内火灾 均一温度 轰燃 均一性指数 compartment fire homogeneous temperature flash over homogeneity index
  • 相关文献

参考文献15

  • 1杜文锋.消防燃烧学[M].北京:中国人民公安大学出版社,2006.
  • 2McCaffrey B J,Quintiere J G,Harkleroad M F.Estimating room fire temperature and the likelihood of flashover using fire test data correlation[J].Fire Technology,1981,17(2):98-119.
  • 3Thomas P H.Modelling of compartment fires[J].Fire Safety Journal,1983,5(3-4):181-190.
  • 4Harmathy T Z.Postflashover fires-an overview of the research at the National Research Council of Canada (NRCC),1970-1985[J].Fire Technology,1986,22:210-233.
  • 5Bφhm B,Hadvig S.Nonconventional fully developed polyethylene and wood compartment fires[J].Combustion and Flame,1982,44(1-3):201-221.
  • 6Welch S,Jowsey A,Deeny S,et al.Bre large compartment fire tests-characterising post-flashover fires for model validation[J].Fire Safety Journal,2007,42(8):548-567.
  • 7Abecassis-Empis C,Reszka P,Steinhaus T,et al.Charactrisation of dalmarnock fire test one[J].Experimental thermal and fluid science,2008,32(7):1334-1343.
  • 8Thomas I,Bennetts I.Fires in enclosures with single ventilation openings-comparison of long and wide enclosures[C].Proceedings of the Sixth IAFSS symposium,1999:941-952.
  • 9Jamie Stern-Gottfried,Guillermo Rein,Luke A.Bisby,et al.Experimental review of the homogeneous temperature assumption in post-flashover compartment fires[J].Fire Safety Journal,2010,45(4):249-261.
  • 10He Y.On experimental data reduction for zone model validation[J].Journal of Fire Sciences,1997,15(2):144-161.

二级参考文献18

  • 1杜文锋.消防燃烧学[M].北京:中国人民公安大学出版社,1997..
  • 2公安部消防局.中国消防年鉴 (2003-2009年版)[M].北京:中国人事出版社,2003-2009.
  • 3Graham T L,Makhviladze G,Roberts J P.On the theory of flashover development[J].Fire Safety Journal,1995,25,229-259.
  • 4Coakley M.Genetic analysis of built environment fires[D].Preston:University of Central Lancashire,2002.
  • 5Stuart R D.An introduction to fourier analysis[M].London:Chapman and Hall,1965.
  • 6Stroud K A.Fourier series and harmonic analysis[M].Cheltenham:Stanley Thorners (Publishers) Ltd,1984.
  • 7Chen A.Empirical and experimental studies of flashover in compartment Fire[D].Preston:University of Central Lancashire,2004.
  • 8Karlsson B,Quintiere J G.The pre-flashover fire.Enclosure Fire Dynamics[M] ,Boca Raton:CRC Press,2000.
  • 9Walton W D,Thomas P H.The SFPE handbook of fire protection engineering (2nd Edition)[M] ,NFPA,1995.
  • 10Huggett C.Estimation of the rate of heat release by means of oxygen consumption[J].J.of Fire and Flammability,1980,12:61-65

共引文献48

同被引文献19

引证文献2

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部