小尺寸房间及走廊内烟气流动规律模拟研究 被引量:2

Simulation study on smoke flow regularity in small size room and corridor
下载PDF
导出
摘要 为研究房间-走廊内烟气流动规律,更直观准确地反映房间内发生火灾后烟气在房间及走廊中的流动状态,为人员疏散及救援提供技术指导,设计小尺寸房间及走廊条件下的烟气流动模型进行实验,并运用FDS火灾模拟软件对相同尺寸的房间及走廊模型烟气流动进行数值模拟。结果显示实验模拟与数值模拟的小尺寸房间及走廊烟气流动规律一致。根据实验及计算机模拟结果给出了火灾初期房间及走廊中人员疏散与自救的若干意见。 In order to research the smoke flow regularity in room and corridor, visually and truthfully reflect the state of smoke flow in room and corridor when the fire occurred in room, and provide the technical guidance for personnel in rescue and safe evacuation, the smoke flow model in small size room and corridor was designed, and the same size model of room and corridor was established to simulate smoke flow regularity by fire dy namic simulator FDS. The results showed that smoke flow regularity in small size of room and corridor by experimental simulation and numerical simulation was the same. According to the results of simulation, several advices about how people rescue themselves and take safe evacuation in room and corridor in ini tial fire was given.
出处 《消防科学与技术》 CAS 北大核心 2012年第3期247-250,共4页 Fire Science and Technology
关键词 小尺寸房间 走廊 烟气流动 实验模拟 数值模拟 small size room corridor smoke flow experimen tal simulation numerical simulation
  • 相关文献

参考文献8

二级参考文献20

  • 1朱伟,侯建德,廖光煊,卢平,厉培德.多层建筑火灾烟气运动的模拟实验研究[J].中国安全科学学报,2004,14(12):18-21. 被引量:8
  • 2卡里尔 E E.燃烧室与工业炉的模拟[M].北京:科学出版社,1987..
  • 3张文良,兰彬,刘军军等..地下商业街火灾烟气流动特性试验研究报告(96-918- 04-01)[R]..成都:公安部四川消防科学研究所,,2000.2....
  • 4Lattimer B Y, Vandsburger U, Roby R J. Transport of high concentrations of carbon monoxide to locations remote the burning compartment[M]. Gaithersburg: National Institute of Standards and Technology, 1997.
  • 5Kaplan H L, Arthur F G, Hartael Principles and Test Methods [M].Co. , 1983.
  • 6G E. Combustion Toxicology Lancaster: Technomic Pub. Morikawa T. Evolution of toxic gases from burning polymeric materials in a small-scale box model[J]. Fire and Materials, 1988, (12):43-49.
  • 7Bryner N, Johnsson R J , Pitts W M. Carbon monoxide production in compartment fires-reduced-scale enclosure test facility[M]. Gaithersburg: National Institute of Standards and Technology, 1994.
  • 8Wieczorek C. Carbon monoxide generation and transport from compartment fires [M]. Virginia: Virginia Polytechnic Institute and State University, 2003.
  • 9Fang Tingyong, Yang Lizhong, Huang Rui, et al. The relationship between smoke concentration some distance down the hallway and the opening of the room of fire origin[J]. Journal of Fire Sciences, 2003, (21) : 305 - 318.
  • 10Yang Lizhong, Feng Wenxing, Ye Junqi. Experimental research on the spatial distribution of toxic gases in the transport of fire smoke[J]. Journal of Fire Sciences, 2008, 26(1):45-62.