摘要 通过三种有机试剂对铅浓度变化结果的对比,得到含2%丙酮的溶液试剂用量及仪器检测性能条件最佳。并对相关参数验证,确证方法标准曲线线性良好,灵敏度增加;计算得到的检出限0.007 mg/L低于现行标准;精密度1%~12%;准确度90%~105%,符合检测要求。为准确、有效检测微量含铅水质提供新方法。 Solution contained 2% acetone was optimum in reagent consumption and instrument detection performance compared with the results of lead concentration changes from three kinds of organic reagents.And the related parameter was validated,standard curve linearity was well,sensitivity was increased,the detection limit 0.007mg/L calculated was lower than the current standard,precision in 1%~12%,accuracy in 90%~105%,which conformed to determination requirements.It was provided to be a new method to determine trace lead in water accurately and effectively.
作者 赵阳 邱坤艳
出处 《广州化工》 CAS 2012年第5期130-131,135,共3页 GuangZhou Chemical Industry
关键词 ICP-AES 丙酮 检测 水质 ICP-AES lead acetone determination water
  • 相关文献

参考文献6

二级参考文献41

  • 1杨振宇,唐建民.开放式微波消化-ICP-MS法快速测定食品中多种微量元素[J].光谱实验室,2005,22(2):322-328. 被引量:21
  • 2周永利,陈金忠,郭庆林,怀素芳,魏艳红.正丁醇对电感耦合等离子体发射光谱的增敏作用[J].光谱实验室,2006,23(6):1326-1329. 被引量:7
  • 3中华人民共和国国家标准.生活饮用水卫生标准[S].GB5749-2006.北京:中国标准出版社.2007.
  • 4中华人民共和国国家标准.地表水环境质量标准[S].GB3838-2002.北京:中国标准出版社,2002.8-9.
  • 5中华人民共和国国家标准.生活饮用水标准检验方法金属指标[S].GB/T5750.6-2006.北京:中国标准出版社,2007.5.
  • 6国家环保总局编.水和废水监测分析方法[M].第4版.北京:中国环境科学出版社.2002.293.
  • 7Chen D H, Hu B, Huang C Z. Chitosan Modified Ordered Mesoporous Silica as Micro-Column Packing Materials for On-Line Flow Injection-Inductively Coupled Plasma Optical Emission Spectrometry Determination of Trace Heavy Metals in Environmental Water Samples[J]. Talanta, 2009,78 (2) : 491-497.
  • 8Babu S H,Kumar K S,Suvardhan K et al. Preconcentration Technique for the Determination of Trace Elements in Natural Water Samples by ICP-AES[J]. Environ. Monit Assess,2007.128(5) :241-249.
  • 9Yayntas O T, Ylmaz S,Turkoglu Met ol. Determination of Heavy Metal Pollution with Environmental Physieochemieal Parameters in Waste Water of Kocabas Stream (Biga,Canakkale, Turkey) by ICP-AES[J]. Environ. Monit Assess, 5007,127(4) :389-397.
  • 10Wennrich R, Mroczek A, Dittrich K et al. Determination of Nonmetals Using ICP-AES-Techniques [J]. Fresenius Journal of Analytical Chemistry, 2004 , 3S2 ( 5 ) :461-469.