X射线皮秒分幅相机的研制 被引量:7

Investigation of picosecond X-ray framing camera
下载PDF
导出
摘要 研制4微带X射线皮秒分幅相机,其微带阴极宽度为6 mm,由幅值为-1.9 kV,宽度为300ps的选通脉冲进行驱动.对X射线皮秒分幅相机进行联调实验,测量相机的固有延迟为42.9 ns,时间分辨率为110 ps,空间分辨率为17.86 lp/mm.由静态空间分辨率图像获得了分幅相机的调制传递函数曲线. A picosecond X-ray framing camera with four microstrip lines was described in this article. The micros- trip line cathode with a width of 6 mm was driven by the gating pulse with a width of 300 ps and an amplitude of - 1.9 kV. The camera was tested, and the experimental results show that the inherent delay of the camera is 42. 9 ns, the temporal resolution is 110 ps, and the spatial resolution is 17. 86 lp/mm. The modulation transfer function curve is obtained from the static spatial resolution imaae.
出处 《深圳大学学报(理工版)》 EI CAS 北大核心 2012年第2期123-128,共6页 Journal of Shenzhen University(Science and Engineering)
基金 国家自然科学基金资助项目(10875080)~~
关键词 光电子学与激光技术 皮秒分幅相机 微通道板 惯性约束聚变 皮秒高压脉冲 X射线相 超快现象 超高速摄影仪 optoelectronics and laser technology picosecond framing camera microchannel plate inertial con-finement fusion picosecond high-voltage pulse X-ray cameras uhrafast phenomena ultra-high speed camera
  • 相关文献

参考文献12

二级参考文献44

共引文献45

同被引文献65

  • 1成金秀,温天舒,朱宗元,常增虎,山冰,刘进元.MCP选通X射线皮秒分幅相机研制进展[J].光学精密工程,1996,4(1):44-48. 被引量:6
  • 2张允刚,刘常春,刘伟,何付志.基于Socket和多线程的远程监控系统[J].控制工程,2006,13(2):175-177. 被引量:55
  • 3成金秀,温天舒,朱宗元,杨存榜,常增虎,山冰,侯继东.MCP选通X射线皮秒分幅相机在ICF中的应用[J].强激光与粒子束,1996,8(1):73-77. 被引量:10
  • 4Liu Jinyuan,Niu Lihong,Peng Wenda. Application of a fast electrical pulse in gated multichannel plate camera[J].Review of Scientific Instruments,2007,(05):055104-1-055104-4.
  • 5Kruschwitz A C,Wu M,Rochau G A. Monte Carlo simulations of microchannel plate detectors.Ⅱ.pulsed voltage results[J].Review of Scientific Instruments,2011,(02):023102-1-023102-8.
  • 6Xiong Gang,Hu Zhimin,Li Hang. One-dimensional space resolving fiat-field holographic grating soft X-ray framing camera spectrograph for laser plasma diagnostics[J].Review of Scientific Instruments,2011,(04):043109-1-043109-5.
  • 7Bell P M,Bradley D K,Kilkenny J D. Radiation hardening of gated x-ray imagers for the National Ignition Facility[J].Review of Scientific Instruments,2010,(10):10E540-1-10E540-3.
  • 8Bell P M,Kilkenny J D,Hanks R. Measurements with a 35-psec gate time microchannel plate camera[A].SPIE,1990.456-464.
  • 9Hilsabeck T J,Hares J D,Kilkenny J D. Pulse-dilation enhanced gated optical imager with 5 ps resolution[J].Review of Scientific Instruments,2010,(10):10E317-1-10E317-6.
  • 10Oertel J A,Archuleta T,Bakeman M. A large-format gated x-ray framing camera[A].Bellingham (USA):SPIE,2004.214-222.

引证文献7

二级引证文献28

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部