样品采用加速溶剂萃取,萃取液依次经复合硅胶和石墨化炭黑柱净化后,采用GC-MS法测定样品中的多氯联苯残留。结果表明,方法检出限为(0.005~0.038)×10-9(湿重),样品加标回收率为68.5%~108.4%,RSD为2.1%~11.8%。本方法具有提取效率高,净化效果好,回收率高,准确灵敏等优点,可应用于海洋沉积物中多氯联苯等持久性有机污染物残留的监测。
A rapid and accurate method was developed for the determination of polychlorinated biphenyls(PCBs) residues in marine sediments by accelerated solvent extraction(ASE) and gas chromatography-mass spectrometry(GC-MS). The target analytes were extracted with hexane/acetone( 1: 1, v/v) by ASE and cleaned up by composite silica gel column and graphitization carbon column. The results demonstrated that the method detection limits was (0. 005 - 0. 038 ) × 10.9 for PC Bs (wet weight). The recovery percentages and RSD of two-level spiked samples were 68.5% - 108.4% and 2.1% - 11.8% for PCBs, respectively. The method was precise, sensitive, and highly efficient in extraction, and has been applied in the actual POPs monitoring in sediments of marine environment.