摘要
通过对某电厂制冷站的测试,对制冷系统的冷机、冷冻水输配系统和冷却水输配系统给出相应的改造措施和节能控制策略,并作了简要分析,以达到节约能源的目的。
Through the test on a power plant refrigeration station,this paper gave corresponding improvement measures and energy-saving control strategies to the refrigerator of refrigeration system,chilled water transmission and distribution system and cooling water transmission and distribution system,and made a brief analysis,in order to achieve the purpose of saving energy.
出处
《山西建筑》
2012年第11期212-213,共2页
Shanxi Architecture
关键词
电厂
制冷站
节能
制冷机
冷冻水
冷却水
power plant
refrigeration station
energy saving
refrigerator
chilled water
cooling water