摘要 采用静态顶空技术和气相色谱质谱仪(GC-MS)联用,检测了进出口油脂中苯、甲苯和二甲苯等苯系物的污染。探讨了色谱柱、恒温温度、平衡时间对测定结果的影响。结果表明,采用HP-5色谱柱,样品恒温温度为90℃,平衡时间为40min时,目标化合物测定效果好。方法检出限小于0.04mg/kg,添加回收率在89.4%(邻二甲苯)~112.5%(甲苯)之间。相对标准偏差(RSD)小于12.4%。该法具有操作简单、能够准确定性、灵敏度较高的特点。 Benzene, toluene, p-xylene and o-xylene in imports and exports oils and fats were analyzed by headspace GC- MS.The effects of chromatographic column, bath temperature and equilibrium time were investigated.The results showed that the optimal conditions of determination were HP-5 chromatographic column, bath temperature 90~C, equilibrium time 40min.The detection limit, recovery and RSD were less than 0.04mg/kg, 89.4%~]12.5% and less than 12.4% .The method was simple,accurate and highly sensitive.
出处 《食品工业科技》 CAS CSCD 北大核心 2012年第6期99-101,共3页 Science and Technology of Food Industry
基金 江苏检验检疫局项目(2009KJ34)
关键词 静态顶空气相色谱质谱法 甲苯 二甲苯 油脂 headspace GC- MS benzene toluene xylene oils and fats