摘要 目的探讨S3肱骨近端锁定钢板治疗肱骨近端骨折的短期疗效。方法应用S3肱骨近端锁定钢板治疗肱骨近端骨折22例,按Neer分型,其中二部分骨折4例,三部分骨折11例,四部分骨折7例。结果随访时间3~15个月,平均6.2个月。术后肩关节功能参照Neer功能评分标准,优17例,良4例,可1例,优良率为95.5%。结论新型的S3肱骨近端锁定钢板独特的设计理念给肱骨近端骨折复位后提供了牢固的软骨下支撑和内固定支架,应用该钢板治疗肱骨近端骨折可获得较好的固定效果。 Objective To explore the initial outcome and efficacy of S3 proximal humerus locking plate in the treatment of proximal humerus fractures. Methods Twenty-two patients with proximal humerus fracture were treated with the S3 proximal humerus locking plate. Most of the fractures were complex, two-part ( n = 4), three-part ( n = 11 ) and four-part ( n = 7 ) fractures according to the Neer classification of the proximal humerus fractures. Results All patients were followed up for 3 - 15 months. There were no complications related to the implant including loosening or breakage of the plate. Good and excellent results were documented in 17 patients and fair results in 4 patients according the Neer scores of shoulder. Conclusion New design concepts of S3 proximal humerus plate provide the subchondral support and the internal fixation support. With the addition of the proper exercise of the shoulder joint, the outcomes would be satisfied.
出处 《苏州大学学报(医学版)》 CAS 2012年第1期116-119,共4页 Suzhou University Journal of Medical Science
关键词 肱骨近端骨折 锁定接骨板 内固定 proximal humerus fracture locking proximal humerus plate internal fixation
  • 相关文献

参考文献8

  • 1Lescheid J,Zdero R,Shah S,et al.The biomechanics oflocked plating for repairing proximal humerus fractures withor without medial cortical support[J].J Trauma,2010,69(5):1235-1242.
  • 2任亚军,孙惠清,姜雪峰,张云庆,周正明.锁定加压钢板治疗肱骨近端骨折的疗效观察[J].苏州大学学报(医学版),2011,31(5):838-839. 被引量:2
  • 3Burton DJC,Watters AT.Management of proximal humer-al fractures[J].Curr Orthop,2006,20(3):222-333.
  • 4Kettler M,Biberthaler P,Braustein V,et al.Treatment ofproximal humeral fractures with the PHILOS angular stableplate:presentation of 225 cases of dislocated fractures[J].Unfallchirurg,2006,109(10):1032-1040.
  • 5Neer CS.Displaced proximal humeral fractures:part I.classification and evaluation[J].Clin Orthop Relat Res,2006,464(1):77-82.
  • 6Edwards SL,Wilson NA,Zhang LQ,et al.Two-part sur-gical neck fractures of the proximal part of the humerus:abiomechanical evaluation of two fixation techniques[J].JBone Joint Surg Am,2006,88(22):2258-2264.
  • 7Gardner MJ,Griffth MH,Dines JS,et al.The extendedanterolateral acromial approach allows minimally invasiveaccess to the proximal humerus[J].Clin Orthop,2005,434(5):123-129.
  • 8Wijgman AJ,Roolker W,Patt W,et al.Open reductionand internal fixation of three and four-part fractures of theproximal part of the humerus[J].J Bone Joint Surg Am,2002,84(11):1919-1925.

二级参考文献8

  • 1张德光,刘福全,刘爱华.肱骨近端骨折锁定加压接骨板内固定治疗肱骨近端骨折[J].中华创伤杂志,2006,22(11):836-838. 被引量:28
  • 2Chu SP, Kelsey JL, Keegan TH, et al. Risk factors for proximal humerus fracture [ J]. Am J Epidemiol, 2004,160 (4) :360 - 367.
  • 3Neer CS . Displaced proximal humeral fractures. I. Classi- fication and evaluation [ J]. J Bone Joint Surg Am, 1970, 52(6) :1077 - 1189.
  • 4Vallier HA. Treatment of proximal humerus fractures [ J ]. J Orthop Trauma,2007,21 (7) :469 -476.
  • 5Geiger EV, Maier M, Kelm A, et al. Functional outcome and complications following PHILOS plate fixation in proxi- mal humeral fractures [ J ]. Acta Orthop Traumatol Turc, 2010,44(1) :1 -6.
  • 6Drosdowech DS, Faber KJ, Athwal GS. Open reduction and internal fixation of proximal humerus fractures [ J ]. Orthop Clin North Am,2008,39 (4) :429 - 439.
  • 7Hepp P, Lill H, Bail H, et al. Where should implants be anchored in the humeral head[J]. Clin Orthop Relat Res, 2003,7(415) :139 - 147.
  • 8Gardner MJ,Weft Y, Barker JU, et al. The importance of medial support in locked plating of proximal humerus frac- tures[J]. J Orthop Trauma, 2007,22(3) :185 -191.

共引文献1

同被引文献23

  • 1Maier D, Jager M, Strohm PC, et al. Treatment of proximal humeral fractures: a review of current concepts enlightened by basic princi- ples[ J]. Acta Chit Orthop Traumatol Cech, 2012,79 ( 4 ) : 307 - 316.
  • 2Roderer G, Erhardt J, Kuster M, et al. Second generation locked plat- ing of proximal humerus fractures : a prospective muhicentre observa- tional study [ J ]. Int Orthop,2011,35 ( 3 ) :425 - 432.
  • 3Gavaskar AS, Muthukumar S, Chowdary N. Biological osteosynthesis of complex proximal humerus fractures: surgical technique and re- sults from a prospective single center trial [ J ]. Arch Orthop Trauma Surg,2010,130 ( 5 ) :667 - 672.
  • 4Gardner MJ, Well Y, Barker JU, et al. The importance of medial support in locked plating of proximal humerus fractures [ J ]. J Or- thop Trauma,2007,21 (3) :185 - 191.
  • 5Jung SW. Indirect reduction maneuver and minimally invasive ap- proach for displaced proximal humerus fractures in elderly patients [ J ]. Clin Orthop Surg ,2013,5 ( 1 ) :66 - 73.
  • 6Acklin YP, Stoffel K, Sommer C. A prospective analysis of the func- tional and radiological outcomes of minimally invasive plating in proximal humerus fractures [ J ]. Injury,2013,44 (4) :456 - 460.
  • 7Little KJ, Riches PE, Fazzi UG. Calcar comminution as prognostic factor of clinical outcome after locking plate fixation of proximal hu- meral fractures [ J]. Injury,2012,43 ( 10 ) : 165 1 - 1656.
  • 8Jung WB, Moon ES, Kim SK, et al. Does medial support decrease major complications of unstable proximal humerus fractures treated with locking plate[ J]. BMC Musculoskelet Disord,2013,22 ( 14 ) : 102.
  • 9薛峰,陈兵乾,盛晓文,陆建民,彭育沁,钱宇峰.MIPPO技术治疗四肢骨折[J].临床骨科杂志,2009,12(2):207-208. 被引量:35
  • 10殷莹,葛宝丰,张功林.骨折生物学内固定技术进展[J].国际骨科学杂志,2010,31(4):242-244. 被引量:22

引证文献1

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部