期刊文献+

600 MW超临界压力锅炉膜式水冷壁截面温度场及鳍片厚度研究 被引量:1

Study on Sectional Temperature Field and Fin Thickness of Membrane Wall for 600MW Super-critical Pressure Boilers
下载PDF
导出
摘要 建立了超临界压力锅炉膜式水冷壁有限元数学模型,并利用ANSYS10.0软件进行截面温度场分布模拟。模拟结果表明:向火侧鳍端为整个膜式水冷壁截面温度最高点;随着鳍片厚度的改变,向火侧鳍端温度存在一个最低值;对于某电厂600MW超临界压力锅炉,鳍片厚度为7~9mm时鳍端温度存在一个最佳值。 A mathematical model of finite element for membrane wall of a super-critical pressure boiler has been set up and a simulation on sectional temperature distribution has been carried out with ANSYS 10.0 software. Simulation results show that the highest temperature occurs at the fin end facing the flame along the whole membrane wall, which has a lowest value with the variation of fin thickness. For a 600 MW super-critical pressure boiler, there exists an optimum fin end temperature with the fin thickness in 7-9 mm.
出处 《发电设备》 2012年第2期84-87,共4页 Power Equipment
关键词 锅炉 膜式水冷壁 有限元模型 温度场分布 鳍片厚度 boiler membrane wall finite element model temperature field distribution fin thickness
  • 相关文献

参考文献7

二级参考文献22

  • 1邹天舒,齐全友,张振兴.超临界直流锅炉膜式水冷壁温度的测量方法[J].东北电力技术,2006,27(3):22-24. 被引量:7
  • 2范谨,贾鸿祥,陈听宽.膜式水冷壁温度场解析[J].热力发电,1996,25(3):10-17. 被引量:32
  • 3郑建学,陈听宽,陈学俊,罗毓珊,毕勤成,吴履琛,王晓为,刘宝森,陈春达.600MW变压运行直流锅炉水冷壁内螺纹管内壁换热特性的研究[J].中国电机工程学报,1996,16(4):271-275. 被引量:25
  • 4Jantaler.A method of determining in local heat flux in boiler furnaces[J].Heater mass transfer,1992,35(06):1 625-1 634.
  • 5北京锅炉厂.锅炉机组热力计算标准方法[M].北京:机械工业出版社,1976..
  • 6樊泉桂.亚临界和超临界压力锅炉[M].北京:中国电力工业出版社,2000..
  • 7中国机械工程学会焊接学会.焊接词典[M].北京:机械工业出版社,1998..
  • 8叶瑞汶.焊接设计简明手册[M].北京:机械工业出版社,1997..
  • 9张汉谦.焊接热效应温度场、残余应力、变形[M].北京:机械工业出版社,1997..
  • 10机械工业技师考评委员会.磨工技师培训教材[M].北京:机械工业出版社,2001..