湿化氧疗在肺部感染后气管切开患者中的应用 被引量:27

原文传递
导出
摘要 自主咳嗽功能差、意识不清或反复误吸的患者一旦出现肺部感染,由于痰液引流不畅,很难控制感染,气管切开术有助于气道分泌物的引流和肺部感染的治疗。但气管切开后,失去上呼吸道的温湿作用,容易导致痰液黏稠,清除气道内分泌物的功能降低,可能反而不利于肺部感染的治疗^[1],因此需要加强这部分患者的气道湿化。目前文献报道的湿化方法主要有微量泵持续泵人湿化液和人下鼻等方法^[2-3],
出处 《中华结核和呼吸杂志》 CAS CSCD 北大核心 2012年第3期222-224,共3页 Chinese Journal of Tuberculosis and Respiratory Diseases
基金 辽宁省医学高峰工程建设项目(200921)
  • 相关文献

参考文献15

  • 1Safdar N, Crnich C J, Maki DG. The pathogenesis of ventilator associated pneumonia: its relevance to developing effective strategies for prevention. Respir Care, 2005, 50:725-739.
  • 2武淑萍,陈京立.输液泵控制气道湿化对减少人工气道并发症的作用[J].中华护理杂志,2003,38(3):193-195. 被引量:253
  • 3Rozsasi A, Leiacker R, Fischer Y, et al. Influence of passive humidification on respiratory heat loss in tracheotomized patients. Head Neck, 2006, 28:609-613.
  • 4姜超美 白淑玲 王辰.人工气道后痰液黏稠度的判断方法和临床意义[J].中华护理杂志,1994,:434-434.
  • 5Gursel G, Demirtas S. Value of APACHEⅡ , SOFA and CPIS scores in predicting prognosis in patients with ventilator-associated pneumonia. Respiration, 2006, 73:503-508.
  • 6American Thoracic Society, Infectious Diseases Society of America. Guidelines for the management of adults with hospital- acquired, ventilator-associated, and heahhcare-associated pneumonia. Am J Respir Grit Care Med, 2005, 171:388-416.
  • 7Lucchini A, Zanella A, Bellani G. Tracheal secretion management in the mechanically ventilated patient: comparison of standard assessment and an acoustic secretion detector. Respir Care, 2011, 56:596-603.
  • 8郑瑞强,杨从山,邱海波,杨毅,黄英姿.热湿交换细菌过滤器预防呼吸机相关肺炎的临床研究[J].中华结核和呼吸杂志,2005,28(3):203-204. 被引量:18
  • 9Lellouehe F, Taill6 S, Lefranqois F, et al. Humidification performance of 48 passive airway humidifiers: comparison with manufacturer data. Chest, 2009, 135:276-286.
  • 10Ryan SN, Rankin AP, Meyer E, et al. Energy balance in the intubated human airway is an indicator of optimal gas conditioning. Crit Care Med, 2002, 30:355-361.

二级参考文献7

  • 1Memish ZA,Oni GA,Djazmati W,et al. A randomized clinical trial to compare the effects of a heat and moisture exchanger with a heated humidifying system on the occurrence rate of ventilator-associated pneumonia. Am J Infect Control,2001,29:301-305.
  • 2Kirton OC,DeHaven B,Morgan J,et al. A prospective,randomized comparison of an in-line heat moisture exchange filter and heated wire humidifiers:rates of ventilator-associated early-onset (community-acquired) or late-onset (hospital-acquired) pneumonia and incidence of endotracheal tube occlusion. Chest,1997,112:1055-1059.
  • 3Lorente L,Lecuona M,Malaga J,et al. Bacterial filters in respiratory circuits:an unnecessary cost?Crit Care Med,2003,31:2126-2130.
  • 4Misset B,Escudier B,Rivara D,et al. Heat and moisture exchanger vs heated humidifier during long-term mechanical ventilation. A prospective randomized study. Chest,1991,100:160-163.
  • 5Emori TG,Culver DH,Horan TC,et al. National nosocomial infections surveillance system (NNIS):description of surveillance methods. Am J Infect Control,1991,19:19-35.
  • 6Martin C,Perrin G,Gevaudan MJ,et al. Heat and moisture exchangers and vaporizing humidifiers in the intensive care unit. Chest,1990,97:144-149.
  • 7Iotti GA,Olivei MC,Braschi A. Mechanical effects of heat-moisture exchangers in ventilated patients. Crit Care,1999,3:R77-R82.

共引文献269

同被引文献275

引证文献27

二级引证文献334

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部