期刊文献+

A Flexible and High Speed Digital Scan Converter for High Frequency Ultrasound Imaging

A Flexible and High Speed Digital Scan Converter for High Frequency Ultrasound Imaging
下载PDF
导出
摘要 This paper presents a flexible and high speed digital scan converter (DSC) with the ability to handle high frequency ultrasound imaging in real-time. The characteristics in imaging system such as focus length of transducer, the swing radius and sampling length etc. could be changed easily in compliance with the researcher's application based on this flexible digital scan converter. Linear interpolation is employed to achieve the coordinate transformations algorithm. Custom-built software is programmed to preliminarily handle the algorithm according to different ultrasound imaging applications. High performance FPGA will implement high speed interpolation calculation based on the preliminary data which are stored in the DDR2 SDRAM from the software. 64 bit 66 MHz PCI is employed to accomplish high speed data transmission. Experiment has shown that more than 500 frame rate could be achieved based on this high speed digital scan converter. The designed flexible and high speed digital scan converter could be used in current FPGA based high frequency ultrasound imaging system. This paper presents a flexible and high speed digital scan converter (DSC) with the ability to handle high frequency ultrasound imaging in real-time. The characteristics in imaging system such as focus length of transducer, the swing radius and sampling length etc. could be changed easily in compliance with the researcher's application based on this flexible digital scan converter. Linear interpolation is employed to achieve the coordinate transformations algorithm. Custom-built software is programmed to preliminarily handle the algorithm according to different ultrasound imaging applications. High performance FPGA will implement high speed interpolation calculation based on the preliminary data which are stored in the DDR2 SDRAM from the software. 64 bit 66 MHz PCI is employed to accomplish high speed data transmission. Experiment has shown that more than 500 frame rate could be achieved based on this high speed digital scan converter. The designed flexible and high speed digital scan converter could be used in current FPGA based high frequency ultrasound imaging system.
出处 《Chinese Journal of Biomedical Engineering(English Edition)》 2011年第3期109-114,共6页 中国生物医学工程学报(英文版)
基金 Hong Kong RGC 5301/09E
关键词 数字扫描变换器 超声成像系统 转换器 高频 坐标转换算法 FPGA实现 高速数据传输 超声显像 flexible digital scan conversion high frequency ultrasound imaging FPGA
  • 相关文献

参考文献9

  • 1Richard WD,Arthur RM.Real-time ultrasonic scan conversion via linear interpolation of oversampled vectors. Ultrasononic Imaging . 1994
  • 2Chang JH,Yen JT,Shung KK.High-speed digital scan converter for high-frequency ultrasound sector scanners. Ultrasonics . 2008
  • 3J.S.Hwang,T.K.Song.A study of the display pixel-based focusing method in ultrasound imaging. Ultrasonic Imaging . 2001
  • 4Foster F S,Pavlin C J,Harasiewicz K A,et al.Advances in ultrasound biomicroscopy. Journal of Ultrasound in Medicine . 2000
  • 5Sun L,Richard WD,Cannata JM,Ching F,Johnson JA,Yen JT,Shung KK.A high frame rate high frequency ultrasonic system for cardiac imaging in mice. IEEE Trans Ultrason Ferroelect Freq Contr . 2007
  • 6X.–C.Xu,C.–H.Hu,L.Sun,J.T.Yen,K.K.Shung."Highfrequency high frame rate ultrasound imaging system for small animal imaging with linear arrays,". Proc.IEEE Utrason.Symp . 2005
  • 7F.S.Foster,G.Liu,J.Mehi,B.S.Starkoski,L.Adamson,Y.Zhou,K.A.Harasiecwicz,L.Zan.High frequency ultrasound imaging:from man to mouse. Proc IEEE Ultrason.Symp . 2000
  • 8Lee M H,Kim J H,Park S B.Analysis of a Scan conversion Algorithm for a Real-time Sector Scanner. IEEE Transactions on Medical Imaging . 1986
  • 9Sun L,Xu X,Richard WD,et al.A high-frame rate duplex ul-trasound biomicroscopy for small animal imaging in vivo. IEEE Transactions on Biomedical Engineering . 2008