摘要
竖埋管地源热泵系统为室内环境控制提供冷热量。在空调工况下,热回收机组可以提供卫生热水。卫生热水的供应在冬夏不同的运行模式下,对地埋管的换热性能影响不同。通过某地源热泵工程设计,分析了冬夏季卫生热水系统在蓄热方式下对地源热泵系统地埋管换热性能的影响。利用卫生热水的蓄热能力,对地埋管换热器在不同工况下的动态换热性能进行了对比分析,并通过数值计算得到了不同运行模式下地埋管的换热性能参数。根据计算结果提出了在该工程负荷特性下的系统调节方式。
The vertical U-tube ground-coupled heat pump system provides cold and heat for the controlling of indoor environment.Under the air-conditioning condition,the vertical U-tube ground-coupled heat pump system with heat recovery can provide domestic hot water.The influence of supplying domestic hot water on the heat transfer performance of ground heat exchangers is different under different operating modes in summer and winter.Through a project design of ground-source heat pump system,the influence of supplying domestic hot water under heat storage mode on the heat transfer performance of ground heat exchangers in summer and winter is respectively analyzed.The dynamic performance of heat exchangers under different working conditions is analyzed,and through numerical calculation,the heat transfer performance parameters of ground heat exchangers under different operating modes are obtained.From the calculation results,the adjusting methods based on the load characteristics of this project represent.
出处
《重庆大学学报(自然科学版)》
EI
CAS
CSCD
北大核心
2012年第3期140-146,共7页
Journal of Chongqing University
基金
重庆市自然科学基金计划资助项目(CQ CSTC
2010BB4235)
关键词
地源热泵
卫生热水
蓄热
地埋管换热性能
ground-source heat pump
domestic hot water
heat storage
the heat transfer performance of ground heat exchangers