摘要 竖埋管地源热泵系统为室内环境控制提供冷热量。在空调工况下,热回收机组可以提供卫生热水。卫生热水的供应在冬夏不同的运行模式下,对地埋管的换热性能影响不同。通过某地源热泵工程设计,分析了冬夏季卫生热水系统在蓄热方式下对地源热泵系统地埋管换热性能的影响。利用卫生热水的蓄热能力,对地埋管换热器在不同工况下的动态换热性能进行了对比分析,并通过数值计算得到了不同运行模式下地埋管的换热性能参数。根据计算结果提出了在该工程负荷特性下的系统调节方式。 The vertical U-tube ground-coupled heat pump system provides cold and heat for the controlling of indoor environment.Under the air-conditioning condition,the vertical U-tube ground-coupled heat pump system with heat recovery can provide domestic hot water.The influence of supplying domestic hot water on the heat transfer performance of ground heat exchangers is different under different operating modes in summer and winter.Through a project design of ground-source heat pump system,the influence of supplying domestic hot water under heat storage mode on the heat transfer performance of ground heat exchangers in summer and winter is respectively analyzed.The dynamic performance of heat exchangers under different working conditions is analyzed,and through numerical calculation,the heat transfer performance parameters of ground heat exchangers under different operating modes are obtained.From the calculation results,the adjusting methods based on the load characteristics of this project represent.
作者 王勇 唐曦
出处 《重庆大学学报(自然科学版)》 EI CAS CSCD 北大核心 2012年第3期140-146,共7页 Journal of Chongqing University
基金 重庆市自然科学基金计划资助项目(CQ CSTC 2010BB4235)
关键词 地源热泵 卫生热水 蓄热 地埋管换热性能 ground-source heat pump domestic hot water heat storage the heat transfer performance of ground heat exchangers
  • 相关文献

参考文献15

  • 1YAVUZTURK C,SPITLER D J.Comparative study to investigate operating and control strategies for hybrid ground source heat pump systems using a short time-step simulation mode[J].ASHRAE Transactions,2000,106(2):192-209.
  • 2KAVANAUGH P S.A design method for hybrid ground-source heat pumps[J].ASHRAE Transactions,1998,104(2):691-698.
  • 3HEPBASLI A.Exergetic modeling and assessment of solar assisted domestic hot water tank integrated ground-source heat pump systems for residences[J].Energy and Buildings,2007,39(12):1211-1217.
  • 4OZGENERA O,HEPBASLI A.Experimental performance analysis of a solar-assisted ground-source heat pump greenhouse heating system[J].Energy and Buildings,2005,37(1):101-110.
  • 5HEPBASLI A,KALINCI Y.A review of heat pump water heating systems[J].Renewable and Sustainable Energy Review,2009,13(6/7):1211-1229.
  • 6TRILLAT-BERDAL V,SOUYRI B,FRAISSE G.Experimental study of a ground-coupled heat pump combined with thermal solar collectors[J].Energy and Buildings,2006,38(12):1477-1484.
  • 7王健敏,廖德富.学生公寓生活热水系统工程优化设计[J].给水排水,2009,35(5):82-85. 被引量:2
  • 8胡松涛,郭潇潇,李绪泉.地源热泵技术在生活热水供应中的应用[J].流体机械,2007,35(9):62-64. 被引量:8
  • 9梅奎.地源热泵热水器系统设计及经济性分析[C]//第13届全国热泵与系统节能技术大会论文集.敦煌:第十三届全国热泵与系统节能技术大会,2008:95-101.
  • 10CUI P,WANG H X,FANG Z H.A simulation study on a new hybrid GCHP system in Hong Kong[C]//Proceedings of the5th International Conference on Sustainable Energy Technologies,August30-September1,2006,Vicenza,Italy.[S.l.]:[S.n.],2006:537-543.

二级参考文献30

共引文献34

同被引文献31

  • 1陈金华,刘猛,吴淑霞,刘勇,樊燕,赖道新.湖水源热泵空调系统取水方式性能分析[J].湖南大学学报(自然科学版),2009,36(S2):79-83. 被引量:10
  • 2李新国,赵军,周倩.U型垂直埋管换热器管群周围土壤温度数值模拟[J].太阳能学报,2004,25(5):703-707. 被引量:51
  • 3赵军,陈雁,李新国.基于跨季节地下蓄热系统的模拟对热储利用模式的优化[J].华北电力大学学报(自然科学版),2007,34(2):74-77. 被引量:16
  • 4周立,葛耀君.全寿命经济分析中折现率的确定[J].上海公路,2007(2):51-54. 被引量:11
  • 5Bhutta MM A B, Hayat N, Bashir M H, et al. CFD applications in various heat exchangers design: a review [J] Applied Thermal Engineering, 2012, 32 : 1-12.
  • 6Shang Y, Li S F, Li H J. Analysis of geo temperature recovery under intermittent operation of ground-source heat pump [J]. Energy and Buildings, 2011,43: 935- 943.
  • 7Zeng H Y, Diao N R, Fang Z H. Heat transfer analysis of borehole in vertical ground heat exchangers [J]. International Journal of Heat and Mass Transfer. 2003, 46:4467-4481.
  • 8Zhang H F, Ge X S, Ye H, et al. Heat conduction and heat storage characteristics of soils [J]. Applied Thermal Engineering, 2007, 27:369-373.
  • 9Wang Y, Wong K K L, Liu Q H, et al. Improvement of energy efficiency {or an open-loop surface water source heat pump system via optimal design of waterintake [J]. Energy and Buildings, 2012,51: 93-100.
  • 10Choi J C, Lee S R, Lee D S. Numerical simulation of vertical ground heat exchangers: intermittent operation in unsaturated soil conditions [J]. Computers and Geotechnies, 2011, 38:949-958.

引证文献3

二级引证文献11

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部