对整流负载时凸极同步发电机定子绕组△及Y联结仿真结果进行分析,绘出反映整流特性的换流重叠角、位移角以及功率因数随负载变化曲线,并对变化趋势进行分析。
This paper deals with the simulation result analysis of three phase synchronous generator with rectified output with stator Y connected, as well as with stator △ connected. The curves of overlap angle, displacement angle and power factor with load are presented, and the tendency of these curves are also described.