摘要
本文用系数倍率法校正了火焰原子吸收分析中Ga403.30nm 对Mn403.31nm 的光谱干扰,用于合成样中Mn 含量的测定,结果令人满意。
The present paper describes the method that use of K - coefficient method to compensate for spectral“overlap” interference of Ga 403.30nm with Mn 403.31nm in AAS.The method has been applied to the determination of manganese in the synthetic samples and the satisfactory results are obtained.
出处
《光谱实验室》
CAS
CSCD
2000年第1期85-87,共3页
Chinese Journal of Spectroscopy Laboratory
基金
江西省自然科学基金
关键词
火焰原子吸收
系数倍率法
光谱干扰
锰测定
Flame Atomic Absorption, K Coefficient Method,Spectral Interference,Manganese Determination.