摘要
结合新建铁路赣韶线信号施工图设计,针对进站信号机、线路所通过信号机有黄闪黄显示时的电路进行了分析,结合其编码电路中所采用的条件,提出了黄闪黄继电器(USUJ)逻辑条件存在的不足和相应的修改建议。
Combined with the signaling construction design of the newly constructed Ganzhou-Shaoguan line,the circuits of home signals and through signals within line servicing post are analyzed when they have USU aspect.According to the requirements of encoding circuit,the deficiencies in USUJ logics are discussed and corresponding revision advice is proposed.
出处
《铁道通信信号》
2012年第3期9-11,共3页
Railway Signalling & Communication