摘要
文章对炉膛IR-3D型吹灰器吹损水冷壁进行了分析,通过对吹灰器喷头起吹位置调整,解决了吹灰器吹损水冷壁的问题。保证了锅炉的安全、长周期运行。
This paper analyzes loss of water-wall blowing of IR-3D Furnace Soot Blower, by adjustment the position of soot blower nozzle, address the issues of loss of water wall soot blower, to ensure the safety of the boiler, and long-term operation.
出处
《科教导刊》
2012年第3期178-179,共2页
The Guide Of Science & Education
关键词
炉膛
吹灰器
起吹位置
分析
措施
furnace
soot blower
blowing position
analysis
measures