摘要 自动化立体高架仓库已经广泛应用于物流仓储等诸多行业,但国内与其相关的消防系统设计规范和标准还较少。从实际案例设计分析并借鉴国外设计规范中的相关规定,介绍案例仓库的实际运行参数和自动喷水灭火系统的设计,并使用专业的水力计算软件对系统进行水力校核以保证系统的安全性。最后,提出对此类仓库进行自动喷水灭火系统设计和安装时应注意的事项。 High rack storage has been widely applied in logistics industries, warehousing, and many other industries. However, related fire-prevention system design codes and standards are rel- atively few in China. Based on practical design analysis and related design codes at abroad, this pa- per introduced the practical operation parameters and sprinkler system design for storage in practi- cal examples and checked the hydraulic calculation to secure the system safety using professional hydraulic calculation software. Finally, some announcements about the sprinkler system design and installation of similar storage were brought forward.
出处 《给水排水》 CSCD 北大核心 2012年第4期71-74,共4页 Water & Wastewater Engineering
关键词 自动化立体高架仓库 自动喷水灭火系统 水力计算 水力校核 High rack storage Sprinkler system Hydraulic calculation Hydraulic calibration
  • 相关文献

参考文献3

  • 1JBT 9018—1999有轨巷道式高层货架仓库设计规范.
  • 2黄晓家,姜文源.自动喷水灭火系统设计手册.北京:中国建筑工业出版社,2004.
  • 3GB 50084-2001(2005年版),自动喷水灭火系统设计规范.