通过对某深基坑临河一侧止水帷幕漏水原因进行分析,详细介绍了基坑漏水发生的原因及处理的方法,结果表明"坑内止水桩+外支撑"方案不仅能很好的解决基坑漏水情况,维护基坑的安全稳定,而且也是较为经济的做法,为预防和处理类似工程事件提供可借鉴的经验。
Base on leakage reason in waterproof curtain of a deep foundation near a river,accident cause and processing method are introduced in detail.The results showed "sealing pile+external support"scheme not only solve the foundation leaks,maintaining security and stability of foundation,but also a more economical approach,which provided useful experience to prevention and treatment similar projects accident.