摘要 简要分析了射频能量对电火工品的危害机制,建立了电火工品发火电路的等效天线模型,推导出了电火工品处于最大拾波方向且阻抗匹配的情况下桥丝接收的最大射频功率数学公式,分析了外界电磁场场强和波长变化对桥丝最大接收功率的影响。 The damage mechanism of radio frequency to EED was analyzed. An equivalent antenna model of electric ignition circuit of EED was established. The mathematical formula of the maximum radio frequency power received by load was deduced when antenna orientation and impedance were optimum. The influence of electronic field intensity and wavelength changing on the maximum power received was analyzed.
机构地区 军械工程学院
出处 《装备环境工程》 CAS 2012年第2期46-48,53,共4页 Equipment Environmental Engineering
关键词 电火工品 天线模型 射频功率 危害评估 EED antenna model radio frequency power damage evaluation
  • 相关文献

参考文献7

二级参考文献11

  • 1李锦荣.电火工品射频阻抗测量及其应用[J].火工品,1995(1):11-14. 被引量:9
  • 2Shankle A,Maiello R.The feasibility of detecting corrosion in electric fuses using the thermal transient technique.AD-A221385,1990.
  • 3沈国舫,金鉴明.中国环境问题院士谈[M].北京:中国纺织出版社,2002.473-485.
  • 4魏光辉,刘尚合.ESD对电发火装置可靠性与安全性影响研究[R].石家庄:中国国防科技报告,1997.
  • 5Ketelaere W D K, Martens L, Braem Y, et al. Calculation of the ESD-pulse parameters and associated uncertainty for ESD-gun calibration[A]. Rodwell M. International Symposium on EMC. IEEE[C]. California: University of California,2000.418-452.
  • 6Wolfsperger H A, Jordan D, Schwab A J. Automatic field distribution measurement inside of enclosures[A]. Rodwell M. International Symposium on EMC. IEEE[C]. California: University of California,2000.237-240.
  • 7刘尚合,朱长清,武占成.电磁脉冲及其效应研究[A].陆建勋."电磁脉冲的产生与防护学术交流会"论文集[C].北京:中国工程院,2003.1-6.
  • 8Laurin J, Zaky G, Balmain K G . On the prediction of digital circuit susceptibility to radiated EMI[J]. IEEE Trans. on EMC,1995,37(4):528-535.
  • 9周彬,秦志春,陈西武,徐振相.用瞬态脉冲试验研究射频试验后电火工品的性能变化[J].火工品,2007(6):21-24. 被引量:3
  • 10李锦荣.电火工品射频发火机制及其射频感度的应用简介[J].火工品,1999(1):51-53. 被引量:11

共引文献109

同被引文献74

引证文献14

二级引证文献19

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部